background image

 

 

 

 

 

 

SPA-PABXR-V2 PABX Recall Voice Recorder

 

 

9

 

 

6  Timing Specification for Off-Hook 

6.1  Calling and Off-Hook 

Afløftning

Indkobling af

øvrigt kredsløb

Indkobling af LF

output

Tlf. linie

t

OUTPUT

t

DETECT

t

DETECT

= 40ms +/- 10ms (50Hz)

   80ms +/- 20ms (25Hz)

=1 s

t

OUTPUT

= 150  ms

t

KLARTONE

t

KLARTONE

  

Off-hook 

Phone line 

Engaging of 

circuit  

 

Engaging of 

LF output 

Summary of Contents for SPA-PABXR-V2

Page 1: ...SPA PABXR V2 PABX Recall Voice Recorder USER MANUAL A100K12122 ...

Page 2: ... of on Hook Line When Connected to Phone Line 4 3 Function Settings 5 3 1 DIP Switch PROG Settings 5 3 2 Jumper J1 settings 5 3 3 Volume P1 5 4 Electrical Specification 6 4 1 Environment 6 5 SPA PABXR V2 Connections 7 5 1 Layout 7 5 2 X150 Input Output 7 5 3 X151 Bidirectional Input 7 5 4 X152 Output 8 5 5 X153 Output 8 5 6 X154 Input 8 5 7 LEDs 8 6 Timing Specification for Off Hook 9 6 1 Calling ...

Page 3: ...t describes the SPA PABXR V2 PABX Recall Voice Recorder Item No Item Name Product Description 3005010169 SPA PABXR V2 PABX Recall Voice Recorder 1 2 Publication Log Revision Date Author Status 1 0 28 10 2014 JS ETRONIC CSU 6 CO documentation 1 1 5 10 2021 HKL Published in Zenitel template ...

Page 4: ...orded The message length is limited to 30 seconds After recording the message is pressed for the selection of zones When 0 is pressed all zones will be selected automatically The message will be played instantly when the line is on hook If zone selection is not performed within 15 seconds the unit will automatically set the line to go on hook If the message is longer than 30 seconds the unit will ...

Page 5: ...cording OFF The message is recorded 4 ON The message is played without delay OFF The message is played with a 5 second delay Change of DIP switch settings requires a power off power on of the unit 3 2 Jumper J1 settings Connecting to PSTN jumper J1 is moved to position PSTN Connecting to TRUNK J1 is moved to position TRUNK In trunk mode the unit can operate without an exchange Connect an audio inp...

Page 6: ...24 VDC 100mA 40 25 Load of NO NC contacts max 250 VRMS 170mA Calling Voltage 30 120 VEFF 25 Hz 2 5 Hz 50 Hz 5 Hz Recorded Tone 425 Hz 25 Hz 22 dBm 0 dBm DC Loop Current 8 mA IMAX according to TBR 21 section 4 7 1 IMAX 60mA 4 1 Environment Working Temperature 15 C to 55 C Humidity 93 RH ...

Page 7: ...tivation signal 11 Output Zone 5 Activation signal 12 Output Zone 6 Activation signal 13 Input Activation signal zone selection It is possible to have your own activation signal Signal here will be outputted to zone selection 1 6 on X150 position 7 12 Load max 250VAC 170mA 14 EARTH 5 3 X151 Bidirectional Input 1 Line a Audio input 2 Line b Audio input 3 Input TI Switch When in TRUNK mode use X151 ...

Page 8: ...ne 5 potential free contact Load max 250VAC 170mA 11 12 Zone 6 potential free contact Load max 250VAC 170mA 5 6 X154 Input 1 2 PAUSE input switch potential free 5 7 LEDs REC Indicates a recording is active PLAY Indicates a playback is active Z1 Indicates current zone is active at playback Zone 1 Z2 Indicates current zone is active at playback Zone 2 Z3 Indicates current zone is active at playback ...

Page 9: ...or Off Hook 6 1 Calling and Off Hook Afløftning Indkobling af øvrigt kredsløb Indkobling af LF output Tlf linie tOUTPUT t DETECT t DETECT 40ms 10ms 50Hz 80ms 20ms 25Hz 1 s tOUTPUT 150 ms tKLARTONE tKLARTONE Off hook Phone line Engaging of circuit Engaging of LF output ...

Page 10: ... Indkobling af LF output tBUSY tBUSY 45 ms 5 ms 6 3 Detection of Missing Loop Current Afløftning Indkobling af øvrigt kredsløb Indkobling af LF output Sløjfestrøm t NO_LOOP_CURRENT t NO_LOOP_CURRENT 0 4 ms 0 1 ms Off hook Phone line Engaging of circuit Engaging of LF output Hook flash Hook off Engaging of circuit Engaging of LF output ...

Page 11: ...certified to meet the requirements in NS EN ISO 9001 Zenitel reserves the right to modify designs and alter specifications without notice ZENITEL PROPRIETARY This document and its supplementing elements contain Zenitel or third party information which is proprietary and confidential Any disclosure copying distribution or use is prohibited if not otherwise explicitly agreed in writing with Zenitel ...

Reviews: