Operating Manual ZEMMLER MULTI SCREEN MS 1600
Operating
MS1600.153.19
Page
36
8.3
Operating with power generator
Before starting the generator ensure that the engine compartment is prevented
against pollution/ particulate emissions and heat. It is possible to realize it with a
flexible metal tube, otherwise it may can result a damage on the machine which is
not included in the warranty.
fig. 8-3: Use of metal tube
8.3.1
Starting the power generator
1.
Open the door (see fig. 8-4) and save the door with the rod.
fig. 8-4: Control unit door opened
Warning
– Risk of crushing bodies or body parts!
No safety of the door through the rod leads to a crushing hazard between the door and
the frame of the machine.
Safe the doors always with the rod.