Remove the
outlet and foam filter cover
from the
vacuum cleaner.
5
Remove the
HEPA outlet filter
from the vacuum cleaner.
6
Replace the used filter with a new one.
HEPA filter ensures an effective filtration for
about 1 year.
7
Replace the
outlet and foam filter cover
.
8
Place your hand in the indent and move the cover
towards . A “click” sound indicates that the cover snapped
on correctly.
FOAM FILTER
1
Remove the
outlet and foam filter cover
from the
vacuum cleaner (see section “HEPA OUTLET FILTER”).
2
Remove the
HEPA outlet filter
from the vacuum cleaner.
3
Remove the
foam filter
. If the foam filter becomes dirty,
it may be washed under running water. Remember to dry the
filter before reinstallation.
To ensure your safety do NOT install a damp or
damaged foam filter.
4
Replace the
foam filter
.
●
Install the
HEPA outlet filter
in the vacuum cleaner and
put the
outlet and foam filter cover
on (see section
“HEPA OUTLET FILTER”).
INLET FILTER
1
Press the
front cover release button
.
2
Remove the
SAFBAG dust bag module
from the
vacuum cleaner chamber.
3
Put out the cover of inlet filter together with installed inlet
filter from the guide rails located on back wall of vacuum
cleaner chamber.
4
Take out the inlet filter from the inlet filter cover.
5
Place the new filter into the
outlet filter protective
cover
. Ensure that the filter rests on the clips located on both
sides of the cover and the filter edges closely adhere to the
filter cover.
6
The
cover of inlet filter
together with installed filter
press home into guide rails to the previous location.
The damaged inlet filter should be replaced
with a new, genuine manufactured product
only.
7
Insert the
SAFBAG dust bag module
to the vacuum
cleaner chamber.
8
Close the cover by pressing it until you hear
a characteristic click – pay attention not to trap the dust bag.
D
E
SAFBAG dust bag disassembly/assembly
F
1
The vacuum cleaner is equipped with safety valve
located in chamber of dust container (bag). It opens
automatically in case of total stopping of suction hose or
total stopping of equipment elements connected thereto, as
well as in case of overfill of dust bag. After opening the valve
one can hear characteristic “whirr” sound inside the vacuum
cleaner.
2
When the
Dust bag full indicator light
comes on when
the nozzle or brush is above the floor, it indicates that the bag
needs to be replaced. The “Dust bag full” indicator light may
come on when the suction hose or connected accessories
become clogged.
3
Switch off the vacuum cleaner by pressing the
button
and unplug the appliance.
4
Press the two side buttons on the end of the hose and
remove the hose end from the inlet opening of the vacuum
cleaner.
5
Press the
front cover release button
and open it.
6
Remove the
SAFBAG dust bag module
from the
vacuum cleaner chamber.
7
While holding the module, pull the frontal part of the bag
plate upwards and remove the bag. Close the SAFBAG bag
cap to close the full bag. Dispose of the full dust bag in the
waste bin.
8
Slide the plate of the new bag in the direction shown in
the picture. The end of the plate should lock in the socket.
The bag cap should be on top. The direction is shown by an
arrow placed on the bag.
●
Put the
SAFBAG module
together with the assembled
bag into the vacuum cleaner container so that the cogs
of the SAFBAG module fit into the holes in the container
wall. Press and close the cover until you hear the
characteristic clicking sound – be careful not to catch the
bag.
Do not vacuum without SAFBAG bag module
installed. The lack of SAFBAG bag module
disables to slam the upper cover of vacuum
cleaner.
ZELMER vacuum cleaners are equipped with SAFBAG dust
bags in the amount indicated in the table. It is recommended
to replace the dust bag if:
a) the “Dust bag full” indicator light will come on*,
b) the safety valve activates*,
c) the vacuum cleaner operates poorly*,
d) the dust bag is full.
* – before replacing the dust bag, ensure that the suction
tube, suction hose and suction head are free of any
blockages.
The number of SAFBAG bags set that can be purchased,
is placed on a sticker located in the vacuum chamber.
Summary of Contents for ZVC605AP
Page 27: ...33 ZVC605 001_v03 Zelmer Zelmer 8 RU 230 V 16 A...
Page 32: ...38 ZVC605 001_v03 K PE...
Page 33: ...39 ZVC605 001_v03 Zelmer Zelmer 8 BG 230 V 16 A...
Page 38: ...44 ZVC605 001_v03 7 8...
Page 39: ...45 ZVC605 001_v03 Zelmer Zelmer 8 UA 230 V 16 A...
Page 44: ...50 ZVC605 001_v03 PE 26663 19848 5 40 1 15150...
Page 45: ...51 ZVC605 001_v03 Zelmer Zelmer 8 ZELMER KZ 16 230...
Page 50: ...56 ZVC605 001_v03 8...
Page 56: ...Notes...