67
ZVC235-001_v03
We advise you to replace the EPA E12 basic filter
(14) with a new one every 6 months of use.
Always replace a damaged EPA E12 basic filter
with a brand new, original one.
OUTLET MICROFILTER
1
In order to replace the outlet microfilter
(13)
press the
blocking mechanism on the cover of the outlet filter, and then
remove the cover of outlet filter out of the vacuum cleaner.
2
Remove the outlet filter from the cover.
If the outlet microfilter
(13)
is dirty, you may replace it with
a new one, clean it or rinse it with running water. Before
reinstalling the filter, make sure it is dry.
For safety reasons, it is unacceptable to install
a wet or damaged outlet microfilter.
3
Situate the new/rinsed filter carefully onto the
4 fastenings of the outlet filter cover with the foam sides
towards themselves.
4
Place the filter cover in such a way that the two
protrusions situated in the lower part of the cover are
inserted into the holes in the body of the vacuum cleaner,
and then press the filter cover to snap the fastening in the
body shut. A characteristic “click” signalizes the filter cover
has been properly installed.
Always replace a damaged microfilter with
a brand new, original one.
Special accessories
The following special accessories may be purchased in retail
outlets:
Parquet brush “BNB” (22)
Is used to clean and polish hard, scratch sensitive surfaces
such as wooden floors, floor panels, parquet, marble, tiles, etc.
Delicate and soft natural bristles ensure maximum vacuum
effectiveness and protects against scratching the cleaned
surface.
After-work procedures, cleaning and
maintenance
1
Press the on/off button to stop the vacuum cleaner.
2
Remove the plug of the cord from the socket.
3
Wind the cord by pressing the cord winder button
(8)
.
Hold the cord when doing it to avoid tangling the cord up or
letting the plug hit the vacuum cleaner.
4
Disconnect the telescopic suction pipe from the nozzle or
brush.
5
Disconnect the suction tube from the hose. In order
to remove the telescopic tube from the hose handle,
simultaneously press the lock
A
and pull the tube in the
direction indicated by the arrow.
E
F
It is forbidden to wash filters in washing
machines or dishwashers.
Filters may be dried only naturally.
Do not use hairdryers, heaters or radiators to
dry filters.
Before replacing the filters make sure the
vacuum cleaner is off, and the plug of the cord
is unplugged from the socket.
EPA E12 BASIC FILTER
It is necessary to periodically clean the EPA E12 basic filter
to remove small fractions of dust.
Remove the CYKLON dust container and empty it, as
described in para.
C
.
1
Pull the fastenings on the cover of the CYKLON dust
container aside, and remove the cover from the container.
If the CYKLON dust container is full, empty it as described in
para.
C
.
2
Remove the protective casing of the EPA E12 basic
filter out of the dust container. In order to do this turn the
protective casing of the EPA E12 basic filter in the direction
given on the symbol „ ” (it is situated along with an arrow
on the protective casing of the EPA E12 basic filter).
●
Clean, wipe, and carefully dry the casing.
3
Remove the EPA E12 basic filter from the container
●
Clean the pleats of the EPA E12 basic filter
(14)
, and if
the filter is damaged, it should be definitely replaced with
a new one. If the EPA E12 basic filter
(14)
is dirty, you
may replace it with a new one, clean it or rinse it with
running water. Before reinstalling the filter, make sure it
is dry.
For safety reasons it is unacceptable to install
a wet or damaged EPA E12 basic filter (14).
4
Place the new/rinsed EPA E12 basic filter
(14)
in the
previously determined spot in the dust container.
5
Situate the protective casing of the EPA E12 basic filter
in the chamber of the container, in the previously determined
spot. Pay attention that the protrusions situated on the flange
of the container are inserted in the sockets of the body of the
container.
6
Turn the protective casing of the EPA E12 basic filter in
the direction given on the symbol „ ” (it is situated along
with an arrow on the protective casing of the EPA E12 basic
filter).
7
Place the cover of the CYKLON dust container on the
container in such a way that the fastening situated in the
front part of the cover is inserted into the projection of the
container. Press the back part of the cover in such a way that
the fastenings are shut tight on the body of the container.
8
Situate the CYKLON dust container with the installed
EPA E12 basic filter
(14)
in the chamber of the vacuum
cleaner. Close the upper cover of the vacuum cleaner by
pressing it, until you hear a characteristic “click.”
D
Summary of Contents for ZVC235SK
Page 25: ...31 ZVC235 001_v03 Zelmer Zelmer 8 230 16 A RU...
Page 30: ...36 ZVC235 001_v03 K PE...
Page 31: ...37 ZVC235 001_v03 Zelmer Zelmer 8 230 V 16 A BG...
Page 36: ...42 ZVC235 001_v03...
Page 37: ...43 ZVC235 001_v03 Zelmer Zelmer 8 230 16 A UA...
Page 42: ...48 ZVC235 001_v03 PE 26663 19848 5 40 1 15150...
Page 63: ...Notes...
Page 64: ...Notes...