REMOTE CONTROLLER
12. Set on/off time indicator or current time.
13. Preset temperature indicator.
14. Cooling mode:
COOL
.
15. Dehumidifying mode:
DRY
.
16. Heating mode:
HEAT- inactive in this model
17. Ventilation mode
FAN
.
18. Mode selection button. Each time you press the button the mode
will change in the following order:
COOL
,
DRY
,
FAN
.
19.
TIMER
button.
Used to set the time of the automatic switch on / switch off of the
appliance. When pressed together with the
HOUR (27)
button, al
-
lows to set the time in the 1–12 hour range with an hourly break.
20. Keypad
HOLD
button.
21.
FAN SPEED
button. Changes the fan speed from
HIGH
,
MED
to
LOW
.
22.
SLEEP
button
– inactive in this model
.
23.
HOLD
indicator.
24.
TEMP
button. Each time you press the button the temperature
will change by 1°C.
25.
ON/OFF
button.
26.
MIN
button. Used to set the current time in minutes.
27.
HOUR
button. Used to set the current time in hours and the auto
-
matic switch on/switch off time in hours.
28.
SWING
button. Used to set the air delivery swing mode (left-right)
or the fixed direction mode of air delivery.
29.
LAMP
button
– inactive in this model
.
30.
CLEAN
button
– inactive in this model
.
Technical specification of the remote controller
Rated voltage
3,0 V
Lowest voltage of CPU emitting signal
2,0 V
Signal receiving range
8 m
Setting the current time
Properly insert two AAA batteries in the battery compartment on the back of the remote controller (see picture).
After installing the batteries the remote controller will automatically set the time to: 0:00.
For instruction purposes, the time will be set to 10:15.
1. Press and hold the
HOUR (27)
for about 3 seconds. The time indicator will begin to flash.
2. Keep pressing the
HOUR (27)
button until 10 a.m. is set.
3. Press the
MIN (26)
button, the minute indicator will begin to flash. Keep pressing the button until it is set to 15.
4. Press the
ON/OFF (25)
button to confirm the set time. The set time will be automatically cancelled if the
ON/OFF
(25)
button is not pressed within 15 seconds.
AIR CONDITIONER FUNCTIONS
The air conditioner has three functions:
COOL
,
DRY
and
FAN
ventilation.
The temperature range for the cooling mode is from 17°C to 31°C, and for the dehumidifying mode is from 20°C to 31°C.
Power source
Plug the appliance only to a grounded AC socket connected to a protection circuit.
●
Do not connect the appliance to a multiple socket outlet which is also being used for other electrical appliances.
●
Insert the plug into a power source. After 2 seconds you will hear a beep. Press the
●
ON/OFF (H)
button on the control panel or the
ON/
OFF (25)
button on the remote controller for the appliance to start operating.
Cooling operation
1. Repeatedly press the
MODE (D)
button on the control panel or the
MODE (18)
button on the remote controller and choose the cooling
mode. The LCD display should show the
COOL
indicator. During the cooling operation always place the air inlet and hot air exhaust hose
outside the room e.g. through an open window.
2. Repeatedly press
TEMP+
or
TEMP- (C)
button on the control panel or the
TEMP (24)
button on the remote controller to select the de
-
sired room temperature at 17 – 31.
3. Press the
FAN SPEED (B)
button on the control panel or the
FAN SPEED (21)
button on the remote controller to select the desired fan
speed:
HIGH
,
MED
, or
LOW
.
4. Press the
SWING (E)
button on the control panel or the
SWING (28)
button on the remote controller to adjust the air delivery direction.
When the LCD display shows the symbol
SWING
; the swing mode is set (left-right). Otherwise the fixed direction mode of air delivery
will be set.
The upper and lower swinging fins
(4)
can be manually adjusted before the start of operation.
ATTENTION: In order to improve the cooling efficiency follow the instructions below:
1. Draw the curtains if the room is directly exposed to the sun.
2. Do not place the air conditioner near other heat sources.
Dehumidifying operation
1. Keep the windows and doors closed for an effective dehumidifying operation.
2. Repeatedly press the
MODE (D)
button on the control panel or the
MODE (18)
button on the remote controller and choose the dehumidi
-
fying mode. The LCD display will show the
DRY
indicator.
During the dehumidifying mode the fan speed cannot be adjusted. (The
FAN SPEED
button is inactive).
3. While using the dehumidifying mode the air conditioner can operate without the air outlet hose.
Open
the back cover
Summary of Contents for 23Z011
Page 37: ...37 37 37 38 38 40 40 40 40 41 41 A 42 A 42 42 42 43 43 43 43 43 K Zelmer SA a RU...
Page 39: ...39 130 40 40 130 2 50 50 60 67 5 123 67 5 123 listwa 1 listwa 2...
Page 43: ...43 O 1 2 o 40 C 3 4 1 2 1 2 3 4 K O K K E2 A E3 E4 E5 1 10 14 2 3 K PE...
Page 44: ...44 44 44 45 45 47 47 47 LCD 47 48 48 49 49 49 49 50 50 50 50 50 Zelmer S A BG...
Page 46: ...46 40 130 2 50 50 60 67 5 123 67 5 123 1 2 130 40...
Page 50: ...50 3 4 1 2 40 C 3 4 1 2 1 2 3 4 E2 E3 E4 E5 1 10 14 2 3...
Page 51: ...51 51 51 52 52 54 54 54 LCD 54 55 55 56 56 56 56 57 57 57 57 57 Zelmer S A UA...
Page 53: ...53 130 40 40 130 2 50 50 60 67 5 123 67 5 123 O 1 2...
Page 57: ...57 1 2 40 C 3 4 1 2 1 2 3 4 E2 E3 E4 E5 1 10 14 2 3 c...