Programming Guides

!

!

Change Programming Password

     

!

     #  Programming Password  #  0  new                                   

Programming Password  #

!

      New Programming Password  # If     

Programming Password lost, perform       
3.2 reset to Factory Default (123456)

!

 Add user card 

!

   

#  Programming Password  #  1  read         

card  # If add multi cards, read cards  
continuously

!

 Set Common Access Password

!

      #  Programming Password  #  21  new                                                                    

Common Access Password  #

!

Common Access Password is only one. 
Open method: Common       Access 
Password #

!

!

 Delete all users

!

      #  Programming Password  #  40 000  #

!

      Delete all cards and PIN except         

Common Access Password

!

 Delete user by read card

!

   #  Programming Password  #  41  read  

card  #

!

If delete multi cards, read cards         
continuously

!

!
!

!

  Key Pad

!

Card read

er

!

Zellabox

!

Technical

 

data

!

4.1.2 Digital Keypad

 

Key

 

Features

!

!

500 Users

!

Water and vandal resistant

!

Backlight (Backlit family, option “B”)

!

Three user levels: normal; secure; master

!

Three modes of operation: normal; bypass; secure

!

Integrated keypad for PIN entry (Piezo electric - Q44 

only)

!

Integrated proximity card reader (Q42 and Q44 only)

!

Selectable PIN code length up to 8 digits

!

Auxiliary input and auxiliary output

!

Ten auxiliary modes including: door ajar;

!

!

 forced door; shunt; door monitor; normal/ secure; LED    

!

     control

!

Input for Request to Exit (REX) button Code search 

feature for easy maintenance of user codes

!

Internal buzzer

!

Vandal proof screw (special tool supplied)

!

Two tri-colour LED indicators for status /programming 

Interface

!

Built-in case and back tamper protection

!

Lockout feature on wrong entries (Keypad/Card 

Tamper)

!

Bell, chime, siren and strobe features available with 

BL-D40

!

Programmable siren time (with BL-D40) 

Programmable lock strike release time. Supplied with 

mounting template for easy installation

!

10

!

Summary of Contents for Cubb

Page 1: ...1 Zellabox User Manual...

Page 2: ...2 Pyrorack 2 3 Uninterruptible Power Supply 2 4 Switchboard 3 Start up procedure 4 Technical Data 4 1 Access Control 4 2 Pyrorack 4 3 Uninterruptible Power Supply 4 4 Switchboard 4 5 Cooling System 4...

Page 3: ...nd robust environment The Micro Data Centre eliminates the need for a server room Our micro data centres offer a robust and dependable answer to the question of housing and securing your networking an...

Page 4: ...ructions 2 1 Overview Important safety note Caution needs to be taken when removing the side panels of the Micro Data Centre in particular when dealing with the 38U as they are heavy we recommend a 2...

Page 5: ...ted Avoid exposure to the fire by products and extinguishing mixture Should it be necessary to enter the area before it is fully ventilated the use of a respirator or other means of protection may be...

Page 6: ...p on or trip over them Do not connect domestic appliances such as hair dryers to UPS output sockets The UPS can be operated by any individuals with no previous experience Connect the UPS system only t...

Page 7: ...e take the precautionary measures specified below and any other measures necessary when working with batteries Remove wristwatches rings and other metal objects Use only tools with insulated grips and...

Page 8: ...DO NOT exceed the cooling system s recommended BTU h specifications listed in the cooling system section as this will overheat the equipment The Zellabox Micro Data Centre is a PLUG N PLAY unit theref...

Page 9: ...nt panel indicators will be as follows Mode Indicator Door Indicator 9 Zellabox Technical data 4 Technical data 4 1 Access control 4 1 1 Metal Keypad Key Features 500 Users Water and vandal resistant...

Page 10: ...Water and vandal resistant Backlight Backlit family option B Three user levels normal secure master Three modes of operation normal bypass secure Integrated keypad for PIN entry Piezo electric Q44 on...

Page 11: ...irements The installation of this product should only be carried out by a competent person and comply with applicable current National or International standards 11 Zellabox Technical data 4 2 Pyrorac...

Page 12: ...base correctly also check that the end of line resistor is in place on the detector base 4 2 3 3 System Fault Cause see all other Fault Indications and Detectors Remedy Check Detectors in place and p...

Page 13: ...t every 3 months the following checks are carried out by a competent person Entries in the Log Book are checked and any necessary action taken Batteries and their connections should be examined and te...

Page 14: ...Zellabox Technical data 4 3 Uninterruptibale power supply 4 3 1 Introduction Please refer to relevant UPS User Manual provided in the Zellabox or alternatively go online 14...

Page 15: ...res Functions The switchboard is plugged or hardwired directly into the building s power source and has a green light on the front panel which MUST be illuminated at all times indicating there is a po...

Page 16: ...but rather switching the cooling system off at the switchboard to reset the controls The recommended temperature setting is between 20 and 23 degrees for maximum efficiency Problem Potential Cause So...

Page 17: ...ratures over 42 degrees within the data centre while a cooling unit is running the alternate unit will start up and provide extra cooling for the Micro Data Centre Once the temperature drops below 20...

Page 18: ...ffer a simple user experience for seamless physical deployment configuration commissioning monitoring and power delivery Zellabox power distribution hardware will remain in place through multiple tech...

Page 19: ...19 Zellabox Zellabox Pty Ltd PO Box 1035 Osborne Park DC Western Australia 6916 AUSTRALIA 1300 117 644 www zellabox com info zellabox com Version 2016 007...

Reviews: