38
7.5 Recharge
This operation is to fill with the refrigerant into the vehicle A/C system
though the Air-Con Service Station. the quantity is measured by load cell and it
must be a vacuum state that the gas could be added into the A/C system.
Usually, if the tank pressure is over than 6 bar, the recharge will be done quickly,
or it need some special solution to resolve it.
1. Press
button to come to recharge process.
Note 1:at this time you can specially keep pressing
button. the charge only from the low side port. And the gas quantity can
not be measured.
Note 2:for this operation, the work tank should have at least 3.5 kg gas
inside. It will show the information if the requirement does not satisfy and
the rest operation is not allowed.It will release some gases if necessary.
Summary of Contents for AC1800
Page 1: ...Automobile Air Con ServiceStation AC1800 Operation Manual...
Page 10: ...9 5 Overview of the Air Con Service Station Used oil bottle Pressure gauge for working tank...
Page 15: ...14...
Page 18: ...17 When at standby mode keep pressing...
Page 36: ...35 Press button more than 50ml...
Page 38: ...37 4 Press the button to print or press to confirm and come back to the standby mode...
Page 44: ...43...
Page 48: ...47 the hose cleaning operation will finished automatically and come back to the standby mode...
Page 58: ...57...