Primo Star / Primo Star iLED
Start-Up and Operation
Carl Zeiss
M60-2-0011 v 08/2008
25
En
g
lish
3.4
Operating the microscope
3.4.1
Setting interpupillary distance and
viewing height
•
Rotate the eyepiece tubes symmetrically toward
or away from one another to adjust the
distance between the tubes to your individual
interpupillary distance (Fig. 18).
The adjustment of the interpupillary distance is
correct when you see only
one
round image while
looking through the two eyepieces!
•
Swivel the eyepiece tubes upward (Fig. 19/
A
) or
B
) to adjust the viewing
height to your individual requirements.
3.4.2
Compensating for ametropia and
inserting the eyepiece pointer or
eyepiece micrometer
The eyepieces (Fig. 20/
3
) are equipped with fold-
over rubber eyecups (Fig. 20/
1
: pulled out;
2
: folded over).
Both eyepieces are suitable for spectacle wearers.
Additionally, they contain a focusing ring for the
compensation of defective vision. The provided
diopter scale serves to facilitate finding the correct
setting.
When using the Primo Star iLED for fluorescence
applications, the special eyecups with light
protection can be used. However, they cannot be
folded over and are not suitable for spectacle
wearers.
If required, an eyepiece pointer or an eyepiece
micrometer can be inserted in one eyepiece.
To this end, follow this procedure:
•
Use Allen key SW 1 mm to loosen the set screw
(Fig. 20/
6
) on the binocular body from below;
remove the eyepiece.
•
5
) by hand from the
eyepiece.
•
Insert the eyepiece pointer (Fig. 20/
4a
) or the
eyepiece micrometer (Fig. 20/
4b
) into the
eyepiece (with the coated side facing your eyes).
Screw in the eyepiece stop again.
Fig. 18
Setting the interpupillary distance
Fig. 19
Adjusting the viewing height
Fig. 20
Inserting the eyepiece pointer or
eyepiece micrometer
Summary of Contents for Primo Star
Page 11: ...Primo Star Primo Star iLED Description Carl Zeiss M60 2 0011 v 08 2008 11 English...
Page 49: ...Primo Star Primo Star iLED Ger tebeschreibung Carl Zeiss M60 2 0011 v 08 2008 11 Deutsch...
Page 125: ...Primo Star Primo Star iLED Descripci n del aparato Carl Zeiss M60 2 0011 v 08 2008 11 Espa ol...
Page 163: ...Primo Star Primo Star iLED Descri o do aparelho Carl Zeiss M60 2 0011 v 08 2008 11 Portugu s...
Page 194: ...Carl Zeiss Primo Star Primo Star iLED 4 M60 2 0011 v 08 2008 1 1 1 3 60 365 625...
Page 196: ...Carl Zeiss Primo Star Primo Star iLED 6 M60 2 0011 v 08 2008 1 5 3 100 240 10 50 60 II...
Page 197: ...Primo Star Primo Star iLED Carl Zeiss M60 2 0011 v 08 2008 7 Carl Zeiss 5...
Page 198: ...Carl Zeiss Primo Star Primo Star iLED 8 M60 2 0011 v 08 2008 1 6 1 2...
Page 199: ...Primo Star Primo Star iLED Carl Zeiss M60 2 0011 v 08 2008 9 3 1 7 Primo Star Primo Star iLED...
Page 200: ...Carl Zeiss Primo Star Primo Star iLED 10 M60 2 0011 v 08 2008 2 2 1...
Page 201: ...Primo Star Primo Star iLED Carl Zeiss M60 2 0011 v 08 2008 11...
Page 232: ...Carl Zeiss Primo Star Primo Star iLED 4 M60 2 0011 v 08 2008 1 1 1 LED LED 3B 60 mW 365 625 nm...
Page 235: ...Primo Star Primo Star iLED Carl Zeiss M60 2 0011 v 08 2008 7 Zeiss Carl Zeiss LED 5...
Page 236: ...Carl Zeiss Primo Star Primo Star iLED 8 M60 2 0011 v 08 2008 1 6 1 2...
Page 238: ...Carl Zeiss Primo Star Primo Star iLED 10 M60 2 0011 v 08 2008 2 2 1...
Page 239: ...Primo Star Primo Star iLED Carl Zeiss M60 2 0011 v 08 2008 11...
Page 243: ...Primo Star Primo Star iLED Carl Zeiss M60 2 0011 v 08 2008 15 IEC 6 1 6 2 6 1 6 3 6 IEC...
Page 250: ...Carl Zeiss Primo Star Primo Star iLED 22 M60 2 0011 v 08 2008 3 2 Primo Star 16 Primo Star...
Page 272: ...Carl Zeiss Primo Star Primo Star iLED 6 M60 2 0011 v 08 2008 1 5 LED LED 3 B 10 50 60 II...
Page 273: ...Primo Star Primo Star iLED Carl Zeiss M60 2 0011 v 08 2008 7 Zeiss Carl Zeiss LED 5...
Page 274: ...Carl Zeiss Primo Star Primo Star iLED 8 M60 2 0011 v 08 2008 1 6 1 2...
Page 275: ...Primo Star Primo Star iLED Carl Zeiss M60 2 0011 v 08 2008 9 3 1 7 iLED...
Page 276: ...Carl Zeiss Primo Star Primo Star iLED 10 M60 2 0011 v 08 2008 2 2 1...
Page 277: ...Primo Star Primo Star iLED Carl Zeiss M60 2 0011 v 08 2008 11...
Page 281: ...Primo Star Primo Star iLED Carl Zeiss M60 2 0011 v 08 2008 15 IEC 2 6 1 6 1 6 3 6 6 IEC...
Page 290: ...Carl Zeiss Primo Star Primo Star iLED 24 M60 2 0011 v 08 2008 3 3 iLED Fixed K hler 17 iLED...