EN - 23

2.8  Setting the CLOCK

1.  Press MENU.
2.  Press 

 or 

 to choose CLOCK.

3.  Press OK to confirm. The day 

indicator is blinking.

4.  Press 

 or 

 to choose the day. 

The following days can be chosen:

 

Q

MON 

=  Monday;

 

Q

TUE  

=  Tuesday; 

 

Q

WED 

=  Wednesday; 

 

Q

THU 

=  Thursday; 

 

Q

FRI 

=  Friday; 

 

Q

SAT 

=  Saturday; 

 

Q

SUN 

=  Sunday.

5.  Press OK to confirm. The hour 

indicator is blinking.

6.  Press 

 or 

 to choose the hour.

7.  Press OK to confirm. The minute 

indicator is blinking.

8.  Press 

 or 

 to choose the 

minutes.

9.  Press OK to confirm. The text says 

SAVED for 2 seconds. The menu is 
automatically closed.

2.9  Setting the COMF 

(Comfort temperature)

The 

ventilation 

unit 

strives 

for 

as 

comfortable  an  air-temperature  supply 
as  possible  on  the  basis  of  a  set  comfort 
temperature.

It is best to set the comfort 

temperature to the same 
temperature as the room 
thermostat (of the central 
heating system).

1.  Press OK. The text says SHIFT for 2 

seconds.

2.  Press MENU before the text SHIFT 

disappears. The text says COMF.

3.  Press OK to confirm. The current set 

temperature is blinking.

4.  Press 

 or 

 to choose the 

comfort temperature.

5.  Press OK to confirm. The text says 

SAVED for 2 seconds. The menu is 
automatically closed.

2.10 Switching the FAN 

When  wanted,  the  supply  (IN)  or  exhaust 
(OUT)  fan  of  the  ventilation  unit  can  be 
turned off manually. This may be desired to 
keep  out  unpleasant  odors  from  outside. 
Bear  in  mind  that  switching  off  a  fan  will 
temporarily  immobilize  your  dwelling’s 
balanced  ventilation  system,  so  do  not 
forget to turn the fans on again.

When can the FAN not be switched?

To  prevent  air  being  sucked  back  from 
the  chimney  of  a  fireplace  the  ventilation 
unit  is  fitted  with  an  open  fire  program. 
When needed the installer or maintenance 
mechanic  can  turn  this  program  on.  If 
the  fire  program  is  turned  on  the  supply 
(IN)  fan  and  exhaust  (OUT)  fan  cannot  be 
turned on or off manually.

When can de supply (IN) fan not be 
turned on?

The  supply  (IN)  fan  cannot  only  be 
operated  manually  but  can  also  be 
controlled automatically by the ventilation 
unit  itself.  This  occurs  in  the  winter  to 
protect  the  ventilation  unit  from  freezing. 
If  the  supply  (IN)  air  is  too  cold  for  the 
ventilation  unit,  the  ventilation  unit  will 
switch  the  supply  (IN)  fan  automatically 
off. In this case the supply (IN) fan cannot 
be turned on manually.

1.  Press OK. The text says SHIFT for 2 

seconds.

2.  Press MENU before the text SHIFT 

disappears. The text says COMF.

3.  Press 

 once. The text says FAN.

4.  Press OK to confirm. The text says 

IN, OFF.

5.  Press 

 or 

 to choose which fan 

to switch on or off. The following 
options can be chosen:

 

Q

IN OFF 

=   Switch off the supply 

fan;

 

Q

OUT OFF  =   Switch off the 

Summary of Contents for ComfoSense CH

Page 1: ... ComfoSense Manual ComfoSense Betriebsanleitung ComfoSense Manuel ComfoSense Manuale ComfoSense Podręcznik ComfoSense Manual ComfoSense Heating Cooling Fresh Air Clean Air ComfoSense CH ComfoSense 55 ComfoSense 67 ...

Page 2: ...he ComfoHood 20 2 5 Switching the ComfoHood Timer 20 2 6 Switching the PARTY TIMER 20 2 7 Ventilation program PROG 21 2 8 Setting the CLOCK 23 2 9 Setting the COMF Comfort temperature 23 2 10 Switching the FAN 23 2 11 Setting PARAM Parameters 24 2 12 CLOCK Back up 24 3 Error messages 25 4 Installation 26 5 Commissioning 26 5 1 Power up 26 5 2 Setting P menu s 26 I Figures 95 ...

Page 3: ...r installation to a maximum of 30 months after production date of the device The warranty becomes invalid if Q The installation has not been carried out according to the applicable regulations Q The defects are due to incorrect connection inexpert use or contamination of the device Q Parts are used that have not been supplied by the manufacturer or repairs are made by unauthorized persons On site ...

Page 4: ...nu Q Exit menu Display 1 Q Text Q Time 2 Value program parameter temperature 3 Q Degree Celsius Fahrenheit Q Percentage 4 ComfoHood 5 Q Supply fan off Q Exhaust fan off 6 Fan speed 7 Night cooling active 8 External sensor overrules the ventilation setting 9 Q Start time of a program Q End time of a program Only available if the mentioned function is connected Shown temperature in F will be changed...

Page 5: ...efault setting can be programmed into the device see Setting the PROG The device is in Automatic operation mode when is pointing to AUTO Press AUTO MAN to switch to the Automatic operation mode 2 2 MAN operation In Manual operation mode the preprogrammed ventilation settings of the device will be overruled temporarily Overrule temporarily Directly press or to increase or decrease the fan speed The...

Page 6: ...rm The text says OFF for 2 seconds 2 5 Switching the ComfoHood Timer This function is only visible if a ComfoHood cooker hood with sensor is connected and a delay time is programmed in PARAM P20 Turning on the ComfoHood Timer 1 Press MENU The text says HOOD 2 Press to choose HOOD TIMER 3 Press OK to confirm The text says ON for 2 seconds The text TIMER is visible in the main screen Turning off the...

Page 7: ...ram with the shortest time is the leading program In the example above Prog 3 overrules Prog 2 When both overlapping programs have an equally long period the program with the smallest program number will be the leading program In the example above Prog 3 overrules Prog 5 Every day in the program starts at 3 00 and ends at 2 59 Setting a program 1 Press MENU 2 Press or to choose PROG 3 Press OK to ...

Page 8: ... for 2 seconds After this SET is blinking The next program number is visible 18 Press MENU to return to the main menu Or go back to step 4 to set another program Deleting a program 1 Press MENU 2 Press or to choose PROG 3 Press OK to confirm SET is blinking The program number is visible 4 Press or to choose the program to delete PROG is blinking The program number is visible 5 Press OK seven times...

Page 9: ... IN or exhaust OUT fan of the ventilation unit can be turned off manually This may be desired to keep out unpleasant odors from outside Bear in mind that switching off a fan will temporarily immobilize your dwelling s balanced ventilation system so do not forget to turn the fans on again When can the FAN not be switched To prevent air being sucked back from the chimney of a fireplace the ventilati...

Page 10: ... 4 Press OK to confirm The parameter number P1 is blinking 5 Press or to choose the main parameter menu number 6 Press OK to confirm A second number next to the chosen number is blinking 7 Press or to choose the sub parameter menu number 8 Press OK to confirm The parameter value appears 9 When the appeared value is blinking press or to change the parameter value Only a parameter value that is blin...

Page 11: ...elf automatically Resetting error messages 1 Press MENU 2 Press OK 4 Installation Disconnect the ventilation unit from the main power before installing the device Always follow local safety regulations The letters mentioned in this chapter refer to the installation figures fig 1 2 or 3 at the back of this document 1 If ordered Attach the wall mounting casing I with the plugs H and screws G to the ...

Page 12: ... result will be 1 Press OK The text says SHIFT for 2 seconds 2 Press MENU before the text SHIFT disappears The text says COMF 3 Press or to choose PARAM 4 Press OK to confirm The parameter number is blinking 5 Press twice to choose PASSW 6 Press OK to confirm The password number 0 appears 7 Press to choose 14 8 Press OK to confirm P3 is blinking 9 Press or to choose the main parameter menu number ...

Page 13: ... in Default Screen 1 Q Clock not visible Default Screen 0 895 0 1 0 Q Night cooling symbol visible in Default Screen 1 Q Night cooling symbol not visible in Default Screen 0 896 0 1 0 Q Degrees in Fahrenheit 1 Q Degrees in Celsius 0 897 0 255 Software version read only value 898 1 5 Quality RF reach Q 1 bad Q 5 good 899 0 1 0 Reset ventilation program PROG Only available if the mentioned function ...

Reviews: