Introduction

The 

ComfoSense 

(henceforth 

called 

“device”) is a control device for residential 
ventilation 

units 

(henceforth 

called 

“ventilation  unit”  or  “HRU”).  The  device 
can  be  used  for  the  ComfoAir  Luxe, 
ComfoD Luxe, WHR Luxe, WHR plus, G90 
and Santos Standard. 

The  device  is  designed  for  the  following 
purposes:
1.  To set a ventilation program for the 

ventilation unit (auto);

2.  To set the ventilation volume of the 

ventilation unit (manual);

3.  To set the parameters of the 

ventilation unit (P menus).

There  are  3  different  variations  of  the 
device (as shown on the front page): 
ComfoSense 55, 67 and CH.
With these 3 variations the device can be 
built-in  in  almost  every  standard  frame. 
In  addition,  the  ComfoSense  67  is  also 
available with a wall-mounting casing.

Applicable pictograms

  Point to watch.

  Risk of: 

- Damage to the device; 
-  Performance of the 

ventilation unit is 
compromised if instructions 
are not observed carefully.

Questions

Please contact the supplier if you have any 
questions. In the back of this document is 
a  list  with  the  contact  details  of  the  main 
suppliers.

1.1  Warranty 

The  manufacturer  provides  warranty  for  a 
period of 24 months after installation to a 
maximum  of  30  months  after  production 
date of the device. 
The warranty becomes invalid if:

Q

The installation has not been carried 
out according to the applicable 
regulations;

Q

The defects are due to incorrect 
connection, inexpert use or 
contamination of the device;

Q

Parts are used that have not been 
supplied by the manufacturer or 
repairs are made by unauthorized 
persons.

On-site  dismantling  and  assembly  costs 
are  not  covered  by  the  terms  of  the 
warranty. This also applies to normal wear 
and  tear.  The  manufacturer  retains  the 
right  to  change  the  construction  and/or 
configuration  of  its  products  at  any  time 
without  being  obliged  to  alter  previously 
delivered products.

1.2  Safety

Electrical dangers

There  is  a  risk  of  electric  shock  during 
installation or maintenance. 
Always  comply  with  safety  regulations  in 
this  document.  Non-compliance  with  the 
safety  regulations,  warnings,  notes  and 
instructions  in  this  document  can  cause 
personal  injury  or  damage  to  the  device. 
Disconnect  the  ventilation  unit  from  the 
main power before opening the housing of 
the device.

Electrostatic discharge (ESD) 

 

There  is  a  risk  that  PCBs  may  be 
damaged  by  an  electrostatic  discharge  if 
the  electronics  have  to  be  replaced.  For 
this  reason,  always  take  ESD-inhibiting 
measures  when  dealing  with  PCBs,  such 
as wearing an antistatic wristband.

Summary of Contents for ComfoSense CH

Page 1: ... ComfoSense Manual ComfoSense Betriebsanleitung ComfoSense Manuel ComfoSense Manuale ComfoSense Podręcznik ComfoSense Manual ComfoSense Heating Cooling Fresh Air Clean Air ComfoSense CH ComfoSense 55 ComfoSense 67 ...

Page 2: ...he ComfoHood 20 2 5 Switching the ComfoHood Timer 20 2 6 Switching the PARTY TIMER 20 2 7 Ventilation program PROG 21 2 8 Setting the CLOCK 23 2 9 Setting the COMF Comfort temperature 23 2 10 Switching the FAN 23 2 11 Setting PARAM Parameters 24 2 12 CLOCK Back up 24 3 Error messages 25 4 Installation 26 5 Commissioning 26 5 1 Power up 26 5 2 Setting P menu s 26 I Figures 95 ...

Page 3: ...r installation to a maximum of 30 months after production date of the device The warranty becomes invalid if Q The installation has not been carried out according to the applicable regulations Q The defects are due to incorrect connection inexpert use or contamination of the device Q Parts are used that have not been supplied by the manufacturer or repairs are made by unauthorized persons On site ...

Page 4: ...nu Q Exit menu Display 1 Q Text Q Time 2 Value program parameter temperature 3 Q Degree Celsius Fahrenheit Q Percentage 4 ComfoHood 5 Q Supply fan off Q Exhaust fan off 6 Fan speed 7 Night cooling active 8 External sensor overrules the ventilation setting 9 Q Start time of a program Q End time of a program Only available if the mentioned function is connected Shown temperature in F will be changed...

Page 5: ...efault setting can be programmed into the device see Setting the PROG The device is in Automatic operation mode when is pointing to AUTO Press AUTO MAN to switch to the Automatic operation mode 2 2 MAN operation In Manual operation mode the preprogrammed ventilation settings of the device will be overruled temporarily Overrule temporarily Directly press or to increase or decrease the fan speed The...

Page 6: ...rm The text says OFF for 2 seconds 2 5 Switching the ComfoHood Timer This function is only visible if a ComfoHood cooker hood with sensor is connected and a delay time is programmed in PARAM P20 Turning on the ComfoHood Timer 1 Press MENU The text says HOOD 2 Press to choose HOOD TIMER 3 Press OK to confirm The text says ON for 2 seconds The text TIMER is visible in the main screen Turning off the...

Page 7: ...ram with the shortest time is the leading program In the example above Prog 3 overrules Prog 2 When both overlapping programs have an equally long period the program with the smallest program number will be the leading program In the example above Prog 3 overrules Prog 5 Every day in the program starts at 3 00 and ends at 2 59 Setting a program 1 Press MENU 2 Press or to choose PROG 3 Press OK to ...

Page 8: ... for 2 seconds After this SET is blinking The next program number is visible 18 Press MENU to return to the main menu Or go back to step 4 to set another program Deleting a program 1 Press MENU 2 Press or to choose PROG 3 Press OK to confirm SET is blinking The program number is visible 4 Press or to choose the program to delete PROG is blinking The program number is visible 5 Press OK seven times...

Page 9: ... IN or exhaust OUT fan of the ventilation unit can be turned off manually This may be desired to keep out unpleasant odors from outside Bear in mind that switching off a fan will temporarily immobilize your dwelling s balanced ventilation system so do not forget to turn the fans on again When can the FAN not be switched To prevent air being sucked back from the chimney of a fireplace the ventilati...

Page 10: ... 4 Press OK to confirm The parameter number P1 is blinking 5 Press or to choose the main parameter menu number 6 Press OK to confirm A second number next to the chosen number is blinking 7 Press or to choose the sub parameter menu number 8 Press OK to confirm The parameter value appears 9 When the appeared value is blinking press or to change the parameter value Only a parameter value that is blin...

Page 11: ...elf automatically Resetting error messages 1 Press MENU 2 Press OK 4 Installation Disconnect the ventilation unit from the main power before installing the device Always follow local safety regulations The letters mentioned in this chapter refer to the installation figures fig 1 2 or 3 at the back of this document 1 If ordered Attach the wall mounting casing I with the plugs H and screws G to the ...

Page 12: ... result will be 1 Press OK The text says SHIFT for 2 seconds 2 Press MENU before the text SHIFT disappears The text says COMF 3 Press or to choose PARAM 4 Press OK to confirm The parameter number is blinking 5 Press twice to choose PASSW 6 Press OK to confirm The password number 0 appears 7 Press to choose 14 8 Press OK to confirm P3 is blinking 9 Press or to choose the main parameter menu number ...

Page 13: ... in Default Screen 1 Q Clock not visible Default Screen 0 895 0 1 0 Q Night cooling symbol visible in Default Screen 1 Q Night cooling symbol not visible in Default Screen 0 896 0 1 0 Q Degrees in Fahrenheit 1 Q Degrees in Celsius 0 897 0 255 Software version read only value 898 1 5 Quality RF reach Q 1 bad Q 5 good 899 0 1 0 Reset ventilation program PROG Only available if the mentioned function ...

Reviews: