5.4 Wall mounting, restricted height and width
450mm
131mm
524mm
minimum 549mm
minimum
332mm
1
2
Mount the unit against a wall
with a minimum mass of
200 kg/m2. The sides should
be stable enough to support
the unit.
The stated height is an indication, and
is dependent on the type of air ducts
and condensation drain selected.
Remove the top 2 screws from the
rear.
If no display is fitted:
Use the air-flow direction sticker on
top of the unit to determine which side
is the rear.
Use the screws removed to secure 1
of the mounting brackets supplied to
the unit.
■
Place the flat side of the mounting
bracket against the unit;
■
Place the sloping side of the
mounting bracket upwards;
3
4
5
Remove the bottom 2 screws from
the rear.
Use the screws removed to secure 2
of the spacers supplied to the unit.
Mount the second mounting bracket
supplied to the wall, ensuring it is
level.
■
Place the flat side of the mounting
bracket against the wall;
■
Place the sloping side of the
mounting bracket downwards;
6
Example of
controllers(s)
7
8
Example siphon
Connect the required controllers(s) as
described in the relevant controller
manual.
We recommend using the
front-most connector for the
ComfoSense.
Fit the ComfoPipe Plus air ducts to
the unit as described in the section on
mounting air ducts.
Fit the siphon to the bottom of the
unit as described in the section on
mounting the condensation drain.
9
10
Example valve
Example grille
11
0
50
100
150
200
250
300
350
400
0
50
100
150
200
250
300
p
st
[Pa
]
Qv [m
3
/h]
100%
40%
30%
15%
90%
80%
70%
60%
50%
Example graph
Hang/slide the unit onto the mounting
bracket to the wall.
Press the side of the 4 spacers
supplied against the 4 corners of the
unit and screw them onto the side of
the unit.
Ensure that the spacers do
not block the removable front.
Fit the valves and/or grilles as
described in the section on mounting
valves and/or grilles.
Programme the required air-flow
volumes and time delays as described
in the service manual.
Fill in the installation report.