6 - EN
EN - 7
5. Commissioning
5.1 Use of the ComfoControl Ease
The overview below summarizes the information that will be displayed on the CC Ease.
Time and date
Actual ventilation setting
Ventilation programme
(AUTO) or manual
ventilation (MANUAL)
Signal to replace
internal
(I)
or external
(E)
filter
Supply air
or exhaust air
ON or OFF
bypass activated
Comfort temperature or
temporary high setting,
analogue programme active
The CC Ease has a number of buttons to operate the ComfoAir and to enter the settings.
These buttons are illustrated below.
This button switches to the highest ventilation setting.
Press once
Boost setting ON.
Press twice
Boost setting OFF.
This button allows you to switch between supply/exhaust.
Press once
SUPPLY OFF (and EXHAUST ON).
Press twice
EXHAUST OFF (and SUPPLY ON).
Press 3 times
SUPPLY and EXHAUST both ON.
This button allows you to display or set the comfort temperature.
Press for less than 2 seconds
READ.
Press for longer than 2 seconds
SET.
This button allows you to adjust two settings.
Press for less than 2 seconds
Programme ventilation setting (AUTO / MANUAL).
Press for longer than 2 seconds
Set date and time.
These buttons allow you to adjust various settings:
In P menu or comfort temperature screen
Set values.
In main screen
enter ventilation setting (A, 1, 2, 3).
While the open fire programme is
activated the supply and exhaust
fan cannot be manually switched
off.
Not all CC Ease operating
functions are supported by each
ventilation system.