background image

8 - EN

EN  - 9

The timer of the temporary high 

setting can be switched off early 
by pressing 

  

or 

2.5   Switching the extractor hood on/

off (optional)

1. Press  .
-  Wait until the ComfoAir switches 

to Setting 3 and the symbol for the 
extractor hood is displayed.

2.  Press “

” to switch off the 

extractor hood.

After switching off the extractor hood the 
ComfoAir returns to the normal ventilation 
setting and the extractor hood symbol 
disappears from the CC Ease.

AUTO

 If a time delay has been 
programmed for the extractor 
hood, then the ComfoAir will 
only switch to the normal 
ventilation setting once the time 
delay has run its course. 

While the time delay is still active, a “t” 
will be displayed instead of the extractor 
hood symbol.

 The timer of the extractor hood time 
delay programme can be switched 
off early by pressing  

 or 

2.6   Switching supply and exhaust fan 

on/off (optional)

While the open fire programme is 

activated, or when an ComfoCool 
is registered, the supply and 
exhaust fan cannot be manually 
switched off.

1. Press   once (first time) to switch 

off the supply fan.

This setting is used when the windows 
are open in the summer. Then fresh air 
is not supplied via the supply fan, but 
through the open windows.

Summary of Contents for ComfoControl Ease

Page 1: ...ComfoControl Ease User manual Cooling Fresh Air Clean Air Heating...

Page 2: ...EN All rights reserved This documentation has been compiled with the utmost care The publisher cannot be held liable for any damage caused as a result of missing or incorrect information in this manua...

Page 3: ...ading and setting the ventilation volume 7 2 4 Temporarily activating high setting 8 2 5 Switching the extractor hood on off optional 9 2 6 Switching supply and exhaust fan on off 9 2 7 Ventilation pr...

Page 4: ...a Zehnder balanced ventilation system with heat recovery The CC Ease is usually mounted on the living room wall It displays all important information about the ventilation system referred to further...

Page 5: ...illustrated below This button switches to the highest ventilation setting Press for less than 2 seconds Extractor hood ON or OFF optional Press for longer than 2 seconds Temporary high setting ON Thi...

Page 6: ...ing the temporary high setting Switching the extractor hood on off optional Switching the supply and exhaust fan on off optional Setting a personal ventilation programme Setting additional ventilation...

Page 7: ...system 2 3 Reading and setting the ventilation volume Reading the ventilation volume The current ventilation volume e g 2 will always be displayed on the CC Ease Normally the ComfoAir regulates the r...

Page 8: ...ed Timer Temporary high setting Use this position during cooking showering and when extra ventilation is briefly required The ComfoAir will switch to the highest ventilation position set in the house...

Page 9: ...or hood then the ComfoAir will only switch to the normal ventilation setting once the time delay has run its course While the time delay is still active a t will be displayed instead of the extractor...

Page 10: ...lation setting to suit your individual situation Examples include weekday and weekend programmes Setting A can not be programmed For the remaining settings eight changeovers per day can be programmed...

Page 11: ...gs and return to the main screen 12 Programme the next ventilation profile stage if required Up to eight ventilation profile stages can be programmed Simply repeat steps 1 to 11 Selecting factory rese...

Page 12: ...eat steps 4 to 7 to enter multiple programmes in succession Or press to return to the P menus so you can repeat steps 2 to 7 Return to main screen 9 Press twice to go back Settings can only be entered...

Page 13: ...extractor hood with temperature sensor Deactivation delay for the extractor hood programme x minutes after operating the extractor hood switch the ComfoAir reverts back to its normal setting 0 Min 180...

Page 14: ...16 weeks P25 Optional Note Only applies to systems fitted with an RF switch Deactivation delay for ventilation setting 3 using After pressing BRIEFLY 2 sec the ComfoAir switches to the high setting fo...

Page 15: ...h a corded extractor hood with temperature sensor Setting the extractor hood ventilation levels When the extractor hood is switched on its ventilation levels can be set x higher than the corresponding...

Page 16: ...m with heat recovery Any other application is seen as inappropriate use and can result in damage to the CC Ease or personal injury for which the manufacturer cannot be held liable The manufacturer is...

Page 17: ...section against the wall 8 Reconnect the power to the ComfoAir 7 Malfunctions If the ComfoAir has a malfunction then in most cases a malfunction alert will appear in the CC Ease screen Malfunction ale...

Page 18: ...dwelling will no longer enjoy mechanical ventilation and this can lead to problems with damp and mould Long term deactivation of the ComfoAir must be prevented Meanings of malfunction alerts Code Desc...

Page 19: ...EN 19...

Page 20: ...Group Nederland B V Lingenstraat 2 8028 PM Postbus 621 8000 AP Zwolle T 31 38 429 69 11 F 31 38 422 56 94 info zehnder jestorkair nl www zehnder jestorkair nl ZGNL Manual_849051024 V0512 EN Subject to...

Reviews: