Time delay values
Sub-menu
description
Mini-
mum
Maxi-
mum
General
Reset
P25
note:
Only applies to systems fit-
ted with an RF switch.
Overrun timer for ventilation setting 3 (using "
").
• After pressing "
" briefly (< 2 sec.), the
ComfoAir will switch to the
high
setting for
‘x’ minutes and then automatically returns
to the
normal
setting.
If any 3-position switch is operated during this
lagging time the ComfoAir will instantly revert
to the ventilation position as set at that time.
1 Min.
20 Min.
10 Min.
P26
note:
Only applies to systems fit-
ted with an RF switch.
Overrun timer for ventilation setting 3 " using
".
• After pressing "
"
continuouSly
(> 2 sec.),
the ComfoAir will switch to the
high
setting
for ‘x’ minutes and then automatically re-
turns to the
normal
setting.
If any 3-position switch is operated during this
lagging time the ComfoAir will instantly revert
to the ventilation position as set at that time.
1 Min.
120 Min. 30 Min.
P27
note:
Only applies to systems fit-
ted with a CC Ease panel or
CC Luxe panel.
Time for the Boost setting.
• After pressing "[
]" on the CC Luxe
panel or after pressing “
” continuosly
(>2 sec.) on the CC Ease panel, the Com-
foAir will switch to the high setting for 'x'
minutes and then automatically returns tot
the NORMAL setting
If any 3-position switch is operated during this
lagging time the ComfoAir will instantly revert
to the ventilation position as set at that time.
0 Min.
120 Min. 30 Min.
P29
(Optional)
Setting the extractor hood ventilation levels.
• When the extractor hood is switched on the
extractor hood ventilation settings can be
set x-% higher than the corresponding 'nor-
mal' ventilation levels.
1%
99%
10%
Menu P9
¨
Status of programmes (from menu P5 and P6 additional programmes)
Status
Sub-menu
description
Activated
P90
Open fire programme active?
Yes (1) / No (0)
P91
Bypass Open?
Yes (1) / No (0)
P92
Geothermal heat exchanger valve
Open?
Yes (1) / No (0)
P93
Afterheater on?
Yes (1) / No (0)
P94
Analogue input (0-10V) active?
Yes (1) / No (0)
P95
Frost protection or Preheater active?
Yes (1) / No (0)
P96
Extractor hood on?
Yes (1) / No (0)
P97
Enthalpy programme active?
Yes (1) / No (0)