TECHNICAL DATA 
 
Limit values: 
- minimum revs 

200 RPM 

- maximum revs 

20000 RPM 

- minimum supply voltage 

8 Volts 

- maximum supply voltage 

16 Volts 

- max. supply voltage for 1 minute 

35 Volts 

- current draw  

                     25 mAmp 

 
Circuit is protected against reverse supply voltage (wrong connection). 
 
Features: 
- CDI charged from hi voltage charging coils (generator) 
- programmable ignition map (3D interpolated) 
- store and load function for 2 ignition maps 
- one input for magnetic pickup 
- TPS input (ignition map is 3D interpolated above TPS33%) 
- external switch for changing ignition map while riding 
- power jet output 
- shift light output 
- quick shift (shift kill) 
- tachometer output 
- advance/retard whole ignition curve 
- three stage rev limit (retard timing, reduced spark, spark off) 
- signal delay compensation 
- timing calculation for every 1 RPM change (1000, 1002, .. , 9805, 9806, ...) 
- easy and fast programming on the field, via hand held programmer 
- programming while machine running - you can immediately see effects 
- monitoring of rev's, TPS position, ignition advance angle, via LCD(hand held programmer) 
- fast processing for high accuracy - delays from 1us 

 

 

Summary of Contents for PCDI-RGT

Page 1: ...ore and load function for 2 ignition maps one input for magnetic pickup TPS input ignition map is 3D interpolated above TPS33 external switch for changing ignition map while riding power jet output sh...

Page 2: ...v limit Static Angle static angle stator position Compensation signal delay compensation from pickup to spark plug TPS enable disable TPS TPS close 0 calibrating TPS close position TPS open 100 calibr...

Page 3: ...tion Nr of Points number of ignition curve points from 4 to 12 1 first ignition curve point 2 second ignition curve point Exit exit submenu Important To avoid wrong processing don t make unreasonable...

Page 4: ...for 100 TPS Exit exit submenu Important To avoid wrong processing don t make unreasonable curve course Every time you make any changes to ignition curve it is automatically saved to number 0 Later you...

Page 5: ...sition for activating power jet Power Jet OFF TPS if TPS enabled throttle position for deactivating power jet Exit exit submenu Example Power jet ON RPM 8000rpm Power jet OFF RPM 10000rpm Power jet ON...

Page 6: ...ccurate How to check if compensation is correct First you must set flat ignition curve Then measure with stroboscope lamp if mark at flywheel moving when changing revs If mark moving then you must cha...

Page 7: ...reading Set 1 for single cylinder engines Set 2 for all twins with wasted spark ignition system Enter Set Ign menu and move to Pulses Per Rev with pressing or and then press enter Change nr of pulses...

Page 8: ...nt is programmed at 1500rpm then below 1500rpm ignition timing is defined with trailing edge of trigger bar idle advance se drawing above and above 1500rmp ignition timing is defined by programmed ign...

Page 9: ...With programmer you can watch revs calculated advance ignition angle and TPS position Information You can connect or disconnect PCDI unit from programmer any time you want without any harm It is not...