background image

 

 

- 8 -

23. MONITORING 

 
Connect 

programmer

 to 

PCDI 

and wait few seconds for activation of 

programmer. 

Fist 

information displayed on the 

programmer

 is software version. 

 
With 

programmer

 you can watch revs, calculated advance ignition angle, PV valve position 

and TPS position. 
 

 
Information!

 

You can connect or disconnect 

PCDI 

unit from 

programmer

 any time you want, without any 

harm. It is not important, if motor running or not and if power supply is connected or not.    
 

Important!

 

Do not use too much force when connecting or disconnecting 

programmer

 unit! 

 
 
24. ERROR 

REPORTS 

 
Two errors can be displayed:  

Program Memory Error 

- when program memory is corrupted. With this error present, 

function of program could be faulty. 

EEPROM Error 

- when eeprom memory is corrupted. All programmable data are stored in 

eeprom memory (curve, rev limit...). With this error present, function of program could be 
faulty. 

You must check all your settings and correct changed.

    

PVerror 1 

– position sensor error, or servo motor disconnected  

PVerror 2 – 

servo motor error (short connection) 

Summary of Contents for PCDI-11V

Page 1: ...m hi voltage charging coils generator programmable ignition map 3D interpolated store and load function for 2 ignition maps one input for magnetic pickup TPS input ignition map is 3D interpolated abov...

Page 2: ...U Load Ign Curve load previously saved ignition curve set from 1 to 2 Save Ign Curve save new ignition curve set from 1 to 2 Ignition Curve ignition curve parameters submenu Advance advance retard who...

Page 3: ...ch between ignition curves but also calculate timing between programmed curves for all TPS positions above 33 From 0 to 33 TPS is used only one ignition curve Enter menu and move to Ignition Curve wit...

Page 4: ...ed Enter menu and move to Advance with pressing or and then press enter Now you can set advance with pressing or in 0 1deg steps and then press enter 7 Set SHIFT LIGHT Enter menu and move to Shift Lig...

Page 5: ...TPS close 0 with pressing or and then press enter Leave throttle at close position and confirm calibrating with pressing enter or exit calibration with pressing Displayed number should be between 0 a...

Page 6: ...ou make any changes to valve curve it is automatically saved to 0 position Then you can save it to any other position number from 1 to 5 17 1 Change Number of Curve Points Move to Nr of Points with pr...

Page 7: ...and then press enter Now you can set open position with pressing or and then press enter Max open position is when curve is set to 100 This open position can be moved to any desired position For RZ35...

Page 8: ...nd if power supply is connected or not Important Do not use too much force when connecting or disconnecting programmer unit 24 ERROR REPORTS Two errors can be displayed Program Memory Error when progr...

Reviews: