background image

1. Safety instructions:

1. Read instructions - Dry-read all safety and operation instructions at least once before starting to work 

with the CCR 24.

2. Heed warnings - All warnings given on the CCR 24 or inside this manual should be strictly followed.

3. Water and moisture - The CCR 24 should never be operated near water, e.g. near a washbowl, bathtub, 

kitchen sink, laundry tub, swimming pool or in a wet basement.

4. Heat - Keep the CCR 24 away from devices that produce heat, e.g. radiators.

5. Object and liquid entry - Do not allow solid objects or liquids to fall into or spill over the CCR 24.

6. Power sources - For protection against electric shock, use only power connectors for the CCR 24 that 

are absolutely proof against protruding contacts.

7. Grounding / protective earth - The CCR 24 must always be operated with effective protective earth. 

Never manipulate or defeat the protective earth means of the unit or power supply.

8. Power cord protection - Power supply cords for the CCR 24 should be routed so that the danger of

pinching by objects, walking upon or stumbling over is excluded. Particular care should be taken to
keep away mechanical strain from the power cable entry and the power plugs.

9. Servicing - The user should not attempt to open or service the CCR 24. For maintenance and servicing,

always refer to qualified repair personnel.

10. Keep instructions - This instruction manual should be retained for future reference.

2. Features

2-way stereo or quasi-3-way operation capability

Balanced inputs and outputs with XLR and 1/4“ phone jack connectors 

24 dB Linkwitz-Riley filters

16 crossover frequencies, selectable via rotary switch

Lowpass phase adjustable between 0 and 180 degrees

20 Hz - 30 kHz bandwidth with 12 dB/oct attenuation of outside-band frequencies

Monaural Sub-Bass output for quasi-3-way operation with fixed crossover frequency 

and switchable phase correction

0 dB or +6 dB input reference level, selectable via internal jumper

+6 dBU signal peak limiter per channel

Output gain controls with -15 dB to +15 dB range and 0 dB center detent position

Protection against accidental operation

• 

Optional add-on EQ board with 2 x 4 full-parametric filters

7

 

CCR 24

Summary of Contents for CCR24

Page 1: ...CCR 24 Bedienungsanleitung Seite 3 6 Owner s Manual Page 7 10 Mode d emploi Page 11 14...

Page 2: ...n syst me complet de renforcement sonore est gale ment disponible en option Nous souhaitons que vous puissiez en retirer beaucoup de plaisir de cr ativit et de succ s avec le CCR 24 Lisez attentivemen...

Page 3: ...r Belastung zu sch tzen 9 Der Benutzer darf keine Wartungs oder Servicearbeiten durchf hren Alle Wartungs und Servicearbeiten m ssen von qualifiziertem Fachpersonal durchgef hrt werden 10 Bewahren Sie...

Page 4: ...anliegt 14 LIMIT LED f r Tiefpass leuchtet rot wenn Einsatzpegel des Limiters erreicht ist 15 Tiefpass GAIN Regler 16 Tiefpass PHASE Regler 17 SIGNAL LED f r Hochpass leuchtet gr n wenn Eingangssignal...

Page 5: ...leuchtet die POWER LED auf der Vorderseite der CCR 24 gr n Drehschalter f r Trennfrequenzen Die Trennfrequenzen der CCR 24 sind ber den X OVER Drehschal ter in 16 Stufen einstellbar wobei jederzeit ei...

Page 6: ...enutzt werden Die Trennfrequenzen sollten auf jeden Fall auf das verwendete Lautsprechersystem abgestimmt werden Vor allem d rfen Hoch t ner zu ihrem Schutz nicht mit zu tiefen Frequenzen belastet wer...

Page 7: ...ted so that the danger of pinching by objects walking upon or stumbling over is excluded Particular care should be taken to keep away mechanical strain from the power cable entry and the power plugs 9...

Page 8: ...nal 14 Lowpass LIMIT LED red indicates when lowpass signal reaches limiter threshold 15 Lowpass LEVEL control 16 Lowpass PHASE control 17 Highpass SIGNAL LED green signalizes incoming signal 18 Highpa...

Page 9: ...hex code rotary switch 60 Hz 80 Hz 100 Hz 125 Hz 150 Hz 200 Hz 250 Hz 300 Hz 600 Hz 800 Hz 1kHz 1 2kHz 1 5kHz 2kHz 2 5kHz 3 kHz Having fixed frequencies has the advantage of 100 tracking accuracy betw...

Page 10: ...system Crossover frequencies should always be selected so that they match your PA speaker configuration Always take care that your high frequency drivers do not become overstressed by too low frequenc...

Page 11: ...d utilisation avant toute utilisation 2 Toutes les indications d attention contenues dans cette notice ou sur l appareil doivent tre suivies scrupuleusement 3 L appareil ne doit pas tre utilis proxim...

Page 12: ...rt en pr sence de signal audio 14 Diode LIMIT s allume en rouge quand le limiteur entre en fonction 15 R glage du gain du passe bas 16 R glage de la phase du passe bas 17 Diode SIGNAL s allume en vert...

Page 13: ...i au r seau lectrique Si la tension secteur est disponible la diode POWER en face avant s allume en vert Rotacteur pour le choix des fr quences de coupure Les fr quences de coupure du CCR 24 sont ajus...

Page 14: ...r quences trop basses Ci dessous nous vous donnons des directives g n rales pour les fr quences de filtrages des haut parleurs Chambre de compression 1 pas inf rieur 2 3 kHz Chambre de compression 2 p...

Page 15: ...CCR 24...

Page 16: ...Zeck Audio Turnhallenweg 6 79183 Waldkirch Phone 49 0 7681 2004 0 Fax 49 0 7681 2004 43 e mail Zeck Audio t online de http www ZeckAudio de...

Reviews:

Related manuals for CCR24