background image

Sub-Bass GAIN control

This 

GAIN 

control is also

electronically located
behind the limiter circuit,
control range is 
-15dB to +15dB.

Sub-Bass phase compensation

The Sub-Bass signal is derived from the lowpass signal by feeding
it through an additional lowpass filter, which, like every similar fil-
ter, produces an inherent phase deviation. This phase distortion
can be compensated for by activating the 

LIN PHASE

switch,

which must be operated in the same way as the other switches on
the CCR 24. The yellow 

MATCHED 

LED indicates that the Sub-

Bass signal is now in phase with the other signals. 

Limiter

The built-in limiter circuit keeps the internal signal levels below a
fixed value. When the Gain controls are properly adjusted accord-
ing to the maximum speaker wattage, the limiter circuit will effec-
tively protect your PA system against overload.

Input reference level setting

The CCR 24 is capable of working at two input reference level
standards, 0 dB and +6 dB, selectable by means of an internal
jumper. If you wish to switch to another input level, execute the
following steps in the given order:

Always unplug the unit from electrical power as your first step

Loosen the screws on the upper side of the unit and remove the     

cover

Look for the jumper on the PCB board, it`s located at the left 

front side (see picture)

Plug or unplug the jumper according to your desired input level  

(see picture). Plugged jumper means +6 dB, unplugged jumper
0dB input level.

Hints for setting

Like with any other sound processing unit, alteration of the CCR 24
settings should always be approached carefully and with some
thought. When using your ear as a guide, keep in mind that the
human ear quickly adapts to a certain (not necessarily appropriate)
EQ curve and easily becomes fooled into taking this sound as a
new reference. In addition to that, the human ear is insensitive to
signal phase and can only detect phase problems when sound
cancellations occur as a result. If possible, always rely on a fre-
quency analyzer for finding the best crossover setting for your PA
system.
Crossover frequencies should always be selected so that they
match your PA speaker configuration. Always take care that your
high-frequency drivers do not become overstressed by too low
frequencies. Below we`ll give you some general guidelines for speaker
crossover frequencies:

1“ high frequency drivers: not below 2 - 3 kHz
2“ high frequency drivers: not below 1 - 2 kHz
Crossover between 12“ and 18“ speakers: 150 - 250 Hz
Crossover between 10“ and 15“ speakers: 250- 500 Hz

Limiter adjustment

The limiter adjustment procedure requires to run your PA system
at maximum volumes for a short time. To avoid hearing damages,
always wear ear-protective devices during limiter adjustments. To
get the most from the CCR 24’s limiter function, always make
adjustments in the following manner:

Connect your CCR 24 to mixing console and power amplifiers.
Turn only the amplifier(s) for the bass channel on.
Set all gain controls on the CCR 24 to -15dB.
Set all level controls of the amplifier to maximum position.
Send a signal to the CCR 24 by turning up the mixer faders to
maximum position. Bring up the lowpass gain control on the CCR 24
until the amplifier just begins to signalize signal clipping. Rotate the
lowpass gain control counterclockwise until the clipping just stops.
Adjust the mixer master faders for your average sound level.
Now adjust the highpass gain controls to match the bass sigal for
an overall balanced sound.

6. EQ board (optional)

A specialized add-on EQ board is available for the CCR 24 on
request. This board allows to boost or attenuate user-defined fre-
quencies, turning the CCR 24 into a complete EQ unit for your PA
system.
Tuning the board to your specified frequencies is done by solder-
ing the frequency-relevant components to the board. The right
values for the components are provided by a PC program, which is
supplied with the board, along with detailed explanations. 
Of course, you can also obtain your personally taylored EQ card
from ZECK on request.

7. Technical specifications

Bandwidth (added): 

20 Hz - 30 kHz

Input sensitivity: 

0 / +6 dBU

Crosstalk: 

-80 dB (15 kHz)

Distortion (THD): 

< 0.03 %

S/R ratio: 

> 90 dB (+6 dBU)

Input impedance: 

44 kohms

Output impedance: 

270 ohms

Dimensions: 

483 x 109 x 44 mm

Warranty: 

2 years

 

CCR 24

   

   

  

  

  

 

  

 

  

 

   

  

  

  

     

    

         

   

     

       

         

 

        

  

     

10

Jumper

VIEWED FROM TOP

FRONT PANEL

Summary of Contents for CCR24

Page 1: ...CCR 24 Bedienungsanleitung Seite 3 6 Owner s Manual Page 7 10 Mode d emploi Page 11 14...

Page 2: ...n syst me complet de renforcement sonore est gale ment disponible en option Nous souhaitons que vous puissiez en retirer beaucoup de plaisir de cr ativit et de succ s avec le CCR 24 Lisez attentivemen...

Page 3: ...r Belastung zu sch tzen 9 Der Benutzer darf keine Wartungs oder Servicearbeiten durchf hren Alle Wartungs und Servicearbeiten m ssen von qualifiziertem Fachpersonal durchgef hrt werden 10 Bewahren Sie...

Page 4: ...anliegt 14 LIMIT LED f r Tiefpass leuchtet rot wenn Einsatzpegel des Limiters erreicht ist 15 Tiefpass GAIN Regler 16 Tiefpass PHASE Regler 17 SIGNAL LED f r Hochpass leuchtet gr n wenn Eingangssignal...

Page 5: ...leuchtet die POWER LED auf der Vorderseite der CCR 24 gr n Drehschalter f r Trennfrequenzen Die Trennfrequenzen der CCR 24 sind ber den X OVER Drehschal ter in 16 Stufen einstellbar wobei jederzeit ei...

Page 6: ...enutzt werden Die Trennfrequenzen sollten auf jeden Fall auf das verwendete Lautsprechersystem abgestimmt werden Vor allem d rfen Hoch t ner zu ihrem Schutz nicht mit zu tiefen Frequenzen belastet wer...

Page 7: ...ted so that the danger of pinching by objects walking upon or stumbling over is excluded Particular care should be taken to keep away mechanical strain from the power cable entry and the power plugs 9...

Page 8: ...nal 14 Lowpass LIMIT LED red indicates when lowpass signal reaches limiter threshold 15 Lowpass LEVEL control 16 Lowpass PHASE control 17 Highpass SIGNAL LED green signalizes incoming signal 18 Highpa...

Page 9: ...hex code rotary switch 60 Hz 80 Hz 100 Hz 125 Hz 150 Hz 200 Hz 250 Hz 300 Hz 600 Hz 800 Hz 1kHz 1 2kHz 1 5kHz 2kHz 2 5kHz 3 kHz Having fixed frequencies has the advantage of 100 tracking accuracy betw...

Page 10: ...system Crossover frequencies should always be selected so that they match your PA speaker configuration Always take care that your high frequency drivers do not become overstressed by too low frequenc...

Page 11: ...d utilisation avant toute utilisation 2 Toutes les indications d attention contenues dans cette notice ou sur l appareil doivent tre suivies scrupuleusement 3 L appareil ne doit pas tre utilis proxim...

Page 12: ...rt en pr sence de signal audio 14 Diode LIMIT s allume en rouge quand le limiteur entre en fonction 15 R glage du gain du passe bas 16 R glage de la phase du passe bas 17 Diode SIGNAL s allume en vert...

Page 13: ...i au r seau lectrique Si la tension secteur est disponible la diode POWER en face avant s allume en vert Rotacteur pour le choix des fr quences de coupure Les fr quences de coupure du CCR 24 sont ajus...

Page 14: ...r quences trop basses Ci dessous nous vous donnons des directives g n rales pour les fr quences de filtrages des haut parleurs Chambre de compression 1 pas inf rieur 2 3 kHz Chambre de compression 2 p...

Page 15: ...CCR 24...

Page 16: ...Zeck Audio Turnhallenweg 6 79183 Waldkirch Phone 49 0 7681 2004 0 Fax 49 0 7681 2004 43 e mail Zeck Audio t online de http www ZeckAudio de...