background image

40

41

 

 

 

 

 

Waxing Sleeves 

 

 

 

FRIADENT Castable Waxing Sleeve

21 

 

 

454330  

– 

 D 3.4 

 

454340  

– 

 D 3.8 

 

454350  

– 

 D 4.5 

 

454360  

– 

 D 5.5 

 

 

 

FRIADENT Cast-to Waxing Sleeve

21/8 

 

 

454630  

– 

 D 3.4 

 

454640  

– 

 D 3.8 

 

454650  

– 

 D 4.5 

 

454660  

– 

 D 5.5 

 

 

 

Castable Waxing Sleeve: Prior to bridge delivery, smooth the contact  

 

 

surface between the crown and abutment, in addition to the screw  

 

 

and screw seat using the FRIADENT Finishers (see page 43). 

 

 

 

Cast-To Waxing Sleeve: Smoothing with finishers is not necessary. 

 

 

464300  

 

FRIADENT MP Screw for Waxing Sleeve

4

 

 

 

We recommend using the 1.22 mm FRIADENT Hex Driver  

 

 

(see page 49) when seating the screw for the waxing sleeve. 

 

 

 

Soldering Analogs 

 

 

454102  

 

FRIADENT Lab Set Soldering Analog for Bridge

 

 

 

FRIADENT Soldering Analog, Universal and  

 

 

Soldering Screw for Bridge 

 

 

454103  

 

FRIADENT Soldering Analog

6

, Universal 

 

 

454207  

 

FRIADENT Soldering Screw For Bridge

4

 

bRIDGEs 

Prosthetics/Laboratory

Prosthetic Fabrication at the Gingival Level: 

Instrument Sets Prosthetics

 

 

 

268020  

XiVE Prosthetic Instrument Set

 

 

 

 

This set includes all clinical instruments necessary for 

 

 

impression making and prosthetic delivery. The instruments 

 

 

are supplied in the XiVE Prosthetic Tray. 

 

 

 

Content:

 

 

 

FRIADENT Ratchet 

 

 

Hand Piece Hex Driver 

0.9 mm/Short 

 

 

Hand Piece Hex Driver 

0.9 mm/Long 

 

 

Hand Piece Hex Driver 

1.22 mm/Short 

 

 

Hand Piece Hex Driver 

1.22 mm/Long 

 

 

Handle for Hand Piece Hex Driver

 

 

 

Ratchet Hex Driver 

0.9 mm/Short 

 

 

Ratchet Hex Driver 

0.9 mm/Long 

 

 

Ratchet Hex Driver 

1.22 mm/Short 

 

 

Ratchet Hex Driver 

1.22 mm/Long 

 

 

Seating Instrument for Attachment Insert and MP Insert 

 

 

 

Hand Piece Seating Instrument for MP Insert Screw 

 

 

Ratchet Seating Instrument for MP Insert Screw 

 

 

Insertion Tool EstheticBase

 

 

 

 

FRIADENT Select Try-In Abutment

 D 3.0/A Straight 

 

 

FRIADENT Select Try-In Abutment

 D 3.4/A Straight 

 

 

FRIADENT Select Try-In Abutment

 D 3.8/A Straight 

 

 

FRIADENT Select Try-In Abutment

 D 4.5/A Straight 

 

 

FRIADENT Select Try-In Abutment

 D 5.5/A Straight 

 

 

FRIADENT Select Try-In Abutment

 D 3.0/A 15° 

 

 

 

FRIADENT Select Try-In Abutment

 D 3.4/A 15° 

 

 

FRIADENT Select Try-In Abutment

 D 3.8/A 15° 

 

 

268025  

XiVE Prosthetic Tray 

 

 

(Empty) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pRoD. No. 

DEsCRIpTIoN 

 

pRoD. No. 

DEsCRIpTIoN 

 

FRIADENT

®

 

Prosthetics

  

for 

XiVE

®

 Implant 

System 

 

Summary of Contents for GX430t

Page 1: ...Product Catalog XiVE Versatility and Simplicity Implant System...

Page 2: ...s reserves the right to make technical changes without notice 3 XiVE plus Implant System FRIADENT Prosthetics for XiVE Implant System Contents XiVE plus Implant System 4 Pre Surgical Planning 6 Implan...

Page 3: ...an essential component for the long term success of implant treatment due to interactions at the implant to bone interface They also agree that initial cellular mechanisms such as migration adhesion p...

Page 4: ...Angled 452220 D 3 4 A 15 15 Angled 452221 D 3 8 A 15 15 Angled 455090 FRIADENT Select Sleeve Basic Set The Basic Set contains one Guide Pin and one FRIADENT Select Sleeve for each implant diameter FRI...

Page 5: ...r vial onto the surgical tray 2 Remove the silicone stopper from the sterile inner vial The implant cover screw is located in the silicone stopper of the sterile inner vial 3 Place the XiVE ratchet or...

Page 6: ...T TempBase4 Retaining Screw 0 9 mm Hex 461279 D 3 0 461280 D 3 4 D 5 5 FRIADENT Implant2 Cover Screw 451120 D 3 0 451130 D 3 4 451140 D 3 8 451150 D 4 5 451160 D 5 5 FRIADENT TempBase The FRIADENT Tem...

Page 7: ...art with D 3 0 and increase in diameter until the final implant diameter is reached DI and DII Bone Posterior 1 Groove Anterior 2 Grooves D I 6 mm D IV 2 mm Bone D I D III Up to 6 mm Bone D IV Up to 2...

Page 8: ...15 Depth Gauge D 2 0 3 XiVE Select Try In Implant D 3 0 XiVE Select Try In Implant D 3 4 XiVE Select Try In Implant D 3 8 XiVE Select Try In Implant D 4 5 XiVE Select Try In Implant D 5 5 Round Drill...

Page 9: ...0 D 4 5 5 5 L 8 261251 D 4 5 5 5 L 9 5 261252 D 4 5 5 5 L 11 261253 D 4 5 5 5 L 13 261255 D 4 5 5 5 L 15 XiVE Anterior6 Depth Stop 261310 o D 2 0 3 0 L 8 261311 o D 2 0 3 0 L 9 5 261312 o D 2 0 3 0 L...

Page 10: ...6 455640 Blade Width 2 0 mm 19 18 Instruments for Implant Placement Other Instruments Prod No Description Prod No Description XiVE plus Implant System 261600 XiVE BoneCondenser Instrument Set Straight...

Page 11: ...Abutment with Bar Coping or Waxing Sleeve XiVE TG plus Implants Implant Abutment Connection Compatible with FRIADENT MP Abutment XiVE plus Implant FRIADENT Cover Screw FRIADENT Gingiva Former FRIADENT...

Page 12: ...IADENT CeraBase Telescopic Abutment FRIADENT Attachment FRIADENT EstheticBase Straight or Angled At Implant Level Pages 26 34 Soft Tissue Punches BoneProfiler In cases where implants are placed subcre...

Page 13: ...or making impressions see page 28 FRIADENT Gingiva Former2 451421 D 3 0 GH 1 451422 D 3 0 GH 2 451423 D 3 0 GH 3 451425 D 3 0 GH 5 451431 D 3 4 GH 1 451432 D 3 4 GH 2 451433 D 3 4 GH 3 451435 D 3 4 GH...

Page 14: ...te The transfer coping GH 3 is used for gingiva up to 3 mm thick Please use the transfer coping GH 5 for gingiva exceeding 3 mm in thickness FRIADENT EsthetiCap Includes 0 9 mm Screw The FRIADENT Esth...

Page 15: ...5 GH 52 FRIADENT Transfer Coping PickUp Technique with PickUp Guide Pin4 D 3 0 with PickUp Guide Pin4 D 3 0 and TransferCap20 D 3 0 D 5 5 451625 D 3 0 GH 34 451622 D 3 0 GH 54 451635 D 3 4 GH 34 45163...

Page 16: ...rse screw set is necessary for horizontally screw retained crowns see page 33 FRIADENT Implant Analog5 454020 D 3 0 454030 D 3 4 454040 D 3 8 454050 D 4 5 454060 D 5 5 FRIADENT Select Try In Abutment2...

Page 17: ...onical 30 3 452551 D 4 5 Anatomical 30 3 452560 D 5 5 Conical 30 3 452561 D 5 5 Anatomical 30 3 We recommend using the FRIADENT CeraBase Tool Set 455750 for prepping the ceramic sleeve of the FRIADENT...

Page 18: ...Implant Level FRIADENT Ball and Socket Attachment Comes standard with insert2 ball attachment screw2 socket9 gold alloy blue silicone ring white plastic ring 453131 D 3 4 GH 1 453132 D 3 4 GH 2 45313...

Page 19: ...ment Insert 462781 GH1 1 ring 462782 GH2 2 rings 462783 GH3 3 rings 462785 GH5 5 rings The MP Abutment Inserts are mounted on the implants with the seating instrument for ball and socket attachment in...

Page 20: ...464050 D 4 5 464060 D 5 5 Bar Copings FRIADENT Gold Bar Coping9 without Screw for Soldering 454230 D 3 4 454240 D 3 8 454250 D 4 5 454260 D 5 5 FRIADENT Titanium Bar Coping2 without Screw for Laser W...

Page 21: ...Set This set includes all clinical instruments necessary for impression making and prosthetic delivery The instruments are supplied in the XiVE Prosthetic Tray Content FRIADENT Ratchet Hand Piece Hex...

Page 22: ...rosthetics Laboratory 455605 FRIADENT Seating Instrument for Transfer Coping 455702 FRIADENT Finisher6 10 for Horizontal Screw Seat 455750 FRIADENT CeraBase Tool Set Contents Medium diamond drill fine...

Page 23: ...like a XiVE plus Implant with an integrated MP Abutment The XiVE TG plus Implant also has a trimodal surface for optimum deposition of hard and soft tissue as well as a unique thread design to aid in...

Page 24: ...bone interface They also agree that initial cellular mechanisms such as migration adhesion proliferation and differentiation have an important impact on bone formation quality density and bone to imp...

Page 25: ...he implant driver The XiVE TG Ratchet or Hand Piece Implant Driver see page 49 is used to place XiVE TG plus Implants The adapter screw is removed with the 0 9 mm FRIADENT Hex Driver after seating the...

Page 26: ...D 4 5 Short impression copings are used for making the impression with an existing prosthesis 251805 XiVE TG PickUp Impression Coping2 D 3 4 D 4 5 with PickUp Guide Pin The XiVE TG PickUp Impression C...

Page 27: ...All straight and angled XiVE TG Abutments are made with a horizontal thread M 1 4 An additional horizontal or transverse screw set see page 33 is necessary for horizontally screw retained crowns 25452...

Page 28: ...y Materials Titanium 1 Ti grade 1 Titanium 2 Ti grade 2 Titanium 3 Ti grade 4 Titanium 4 Ti6 AL4 V Aluminum Magnesium 5 AlMg3 Stainless steel 6 DIN 1 4305 Brass 7 CuZn Cast To alloy 8 Au 60 Pt 19 Pd 2...

Page 29: ...ENTSPLY International Inc DENTSPLY Tulsa Dental Specialties DENTSPLY International Inc 5100 E Skelly Drive Suite 300 Tulsa OK 74135 1 800 662 1202 1 800 597 2779 fax www tulsadentalspecialties com Pro...

Reviews: