background image

47

CAsEs:

• Where a transgingival implant design is indicated

• Where temporary and final components are  

needed for simple and fast prosthetic restoration

• Requiring increased primary stability for early or immediate implant function* 

• With atrophied ridges where augmentation is not desired or indicated,  

or cases with multiple implant restorations in the posterior region

• Where a cylindrical implant design is advantageous –  

particularly in the posterior region 

• Where the local bone must be maximized —  

implant lengths available range from 8 to 18 mm

mACRo-DEsIGN

XiVE plus Implant’s cylinder shape design for internal condensation of the peri-implant bone, 
can prevent trauma and increase primary implant stability, even in spongy bone.

mICRo-DEsIGN

The innovative thread design of XiVE plus Implants, when combined with the class-specific 
bone preparation of the implant site, can provide torque stabilization in all bone qualities.

sURFACE DEsIGN

DENTSPLY Friadent pioneered the first micro-retentive grit-blasted/acid-etched titanium 
surface over 15 years ago. Today, this surface design still stands true. Our latest Implant 
Surface Technology, FRIADENT plus, is the result of osseointegration research, combined 
with DENTSPLY Friadent’s expertise in the field of micro- and macro- structured surfaces. 
Scientists and clinicians agree, implant surfaces can be an essential component for the 
long-term success of implant treatment, due to interactions at the implant-to-bone interface. 
They also agree that initial cellular mechanisms such as migration, adhesion, proliferation 
and differentiation have an important impact on bone formation, quality, density and bone-
to-implant contact. DENTSPLY Friadent focused its research on developing a homogenous 
surface morphology that may positively influence cell attachment and bone apposition.

* Immediate loading is restricted to the anterior mandible, based on four intraforaminally 
placed implants, and not indicated for single, unsplinted implants. Patients must be subject 
for dental treatment with endosseous implants.

FRIADENT plus Surface S.E.M.

46

Implant Placement

XiVE TG sTERIlE pACkAGING FoR sCREw ImplANTs

All FRIADENT Screw Implants are gamma-sterilized and packaged in transparent double-glass 
vials. The color-coded cap is sealed with an adhesive label.

 

• Transparent Outer Vial (Non-Sterile) – 

 

 

Provides clear view of contents

 

• Color-Coded Cap (Non-Sterile) – 

 

 

Identifies the implant length

 

• Sterile Inner Vial with Implant Retaining Stopper –  

 

 

 

 

Provides fast, safe, no-touch placement of the implant

 

• Removable Labels –  

 

 

Provide easy and reliable documentation

XiVE TG TRANsGINGIVAl sCREw ImplANTs oFFER  

“ToUCh-FREE” ImplANT DElIVERy:

1.  Remove the outer vial cap (non-sterile) and drop the sterile inner vial onto  

the surgical tray.

2.  Place the XiVE TG Ratchet or Hand Piece Implant Driver onto the adapter screw.

3.  Remove the implant without touching the inner vial.

4.  Remove the implant holder.

5.  Insert the XiVE TG Implant, as outlined in the Instructions For Use.

The undamaged label indicates that the sterile package 
has not been opened and ensures product sterility.

X

iV

E

®

 

TG

 

pl

us

  

Im

pl

an

t S

ys

te

m

Summary of Contents for GX430t

Page 1: ...Product Catalog XiVE Versatility and Simplicity Implant System...

Page 2: ...s reserves the right to make technical changes without notice 3 XiVE plus Implant System FRIADENT Prosthetics for XiVE Implant System Contents XiVE plus Implant System 4 Pre Surgical Planning 6 Implan...

Page 3: ...an essential component for the long term success of implant treatment due to interactions at the implant to bone interface They also agree that initial cellular mechanisms such as migration adhesion p...

Page 4: ...Angled 452220 D 3 4 A 15 15 Angled 452221 D 3 8 A 15 15 Angled 455090 FRIADENT Select Sleeve Basic Set The Basic Set contains one Guide Pin and one FRIADENT Select Sleeve for each implant diameter FRI...

Page 5: ...r vial onto the surgical tray 2 Remove the silicone stopper from the sterile inner vial The implant cover screw is located in the silicone stopper of the sterile inner vial 3 Place the XiVE ratchet or...

Page 6: ...T TempBase4 Retaining Screw 0 9 mm Hex 461279 D 3 0 461280 D 3 4 D 5 5 FRIADENT Implant2 Cover Screw 451120 D 3 0 451130 D 3 4 451140 D 3 8 451150 D 4 5 451160 D 5 5 FRIADENT TempBase The FRIADENT Tem...

Page 7: ...art with D 3 0 and increase in diameter until the final implant diameter is reached DI and DII Bone Posterior 1 Groove Anterior 2 Grooves D I 6 mm D IV 2 mm Bone D I D III Up to 6 mm Bone D IV Up to 2...

Page 8: ...15 Depth Gauge D 2 0 3 XiVE Select Try In Implant D 3 0 XiVE Select Try In Implant D 3 4 XiVE Select Try In Implant D 3 8 XiVE Select Try In Implant D 4 5 XiVE Select Try In Implant D 5 5 Round Drill...

Page 9: ...0 D 4 5 5 5 L 8 261251 D 4 5 5 5 L 9 5 261252 D 4 5 5 5 L 11 261253 D 4 5 5 5 L 13 261255 D 4 5 5 5 L 15 XiVE Anterior6 Depth Stop 261310 o D 2 0 3 0 L 8 261311 o D 2 0 3 0 L 9 5 261312 o D 2 0 3 0 L...

Page 10: ...6 455640 Blade Width 2 0 mm 19 18 Instruments for Implant Placement Other Instruments Prod No Description Prod No Description XiVE plus Implant System 261600 XiVE BoneCondenser Instrument Set Straight...

Page 11: ...Abutment with Bar Coping or Waxing Sleeve XiVE TG plus Implants Implant Abutment Connection Compatible with FRIADENT MP Abutment XiVE plus Implant FRIADENT Cover Screw FRIADENT Gingiva Former FRIADENT...

Page 12: ...IADENT CeraBase Telescopic Abutment FRIADENT Attachment FRIADENT EstheticBase Straight or Angled At Implant Level Pages 26 34 Soft Tissue Punches BoneProfiler In cases where implants are placed subcre...

Page 13: ...or making impressions see page 28 FRIADENT Gingiva Former2 451421 D 3 0 GH 1 451422 D 3 0 GH 2 451423 D 3 0 GH 3 451425 D 3 0 GH 5 451431 D 3 4 GH 1 451432 D 3 4 GH 2 451433 D 3 4 GH 3 451435 D 3 4 GH...

Page 14: ...te The transfer coping GH 3 is used for gingiva up to 3 mm thick Please use the transfer coping GH 5 for gingiva exceeding 3 mm in thickness FRIADENT EsthetiCap Includes 0 9 mm Screw The FRIADENT Esth...

Page 15: ...5 GH 52 FRIADENT Transfer Coping PickUp Technique with PickUp Guide Pin4 D 3 0 with PickUp Guide Pin4 D 3 0 and TransferCap20 D 3 0 D 5 5 451625 D 3 0 GH 34 451622 D 3 0 GH 54 451635 D 3 4 GH 34 45163...

Page 16: ...rse screw set is necessary for horizontally screw retained crowns see page 33 FRIADENT Implant Analog5 454020 D 3 0 454030 D 3 4 454040 D 3 8 454050 D 4 5 454060 D 5 5 FRIADENT Select Try In Abutment2...

Page 17: ...onical 30 3 452551 D 4 5 Anatomical 30 3 452560 D 5 5 Conical 30 3 452561 D 5 5 Anatomical 30 3 We recommend using the FRIADENT CeraBase Tool Set 455750 for prepping the ceramic sleeve of the FRIADENT...

Page 18: ...Implant Level FRIADENT Ball and Socket Attachment Comes standard with insert2 ball attachment screw2 socket9 gold alloy blue silicone ring white plastic ring 453131 D 3 4 GH 1 453132 D 3 4 GH 2 45313...

Page 19: ...ment Insert 462781 GH1 1 ring 462782 GH2 2 rings 462783 GH3 3 rings 462785 GH5 5 rings The MP Abutment Inserts are mounted on the implants with the seating instrument for ball and socket attachment in...

Page 20: ...464050 D 4 5 464060 D 5 5 Bar Copings FRIADENT Gold Bar Coping9 without Screw for Soldering 454230 D 3 4 454240 D 3 8 454250 D 4 5 454260 D 5 5 FRIADENT Titanium Bar Coping2 without Screw for Laser W...

Page 21: ...Set This set includes all clinical instruments necessary for impression making and prosthetic delivery The instruments are supplied in the XiVE Prosthetic Tray Content FRIADENT Ratchet Hand Piece Hex...

Page 22: ...rosthetics Laboratory 455605 FRIADENT Seating Instrument for Transfer Coping 455702 FRIADENT Finisher6 10 for Horizontal Screw Seat 455750 FRIADENT CeraBase Tool Set Contents Medium diamond drill fine...

Page 23: ...like a XiVE plus Implant with an integrated MP Abutment The XiVE TG plus Implant also has a trimodal surface for optimum deposition of hard and soft tissue as well as a unique thread design to aid in...

Page 24: ...bone interface They also agree that initial cellular mechanisms such as migration adhesion proliferation and differentiation have an important impact on bone formation quality density and bone to imp...

Page 25: ...he implant driver The XiVE TG Ratchet or Hand Piece Implant Driver see page 49 is used to place XiVE TG plus Implants The adapter screw is removed with the 0 9 mm FRIADENT Hex Driver after seating the...

Page 26: ...D 4 5 Short impression copings are used for making the impression with an existing prosthesis 251805 XiVE TG PickUp Impression Coping2 D 3 4 D 4 5 with PickUp Guide Pin The XiVE TG PickUp Impression C...

Page 27: ...All straight and angled XiVE TG Abutments are made with a horizontal thread M 1 4 An additional horizontal or transverse screw set see page 33 is necessary for horizontally screw retained crowns 25452...

Page 28: ...y Materials Titanium 1 Ti grade 1 Titanium 2 Ti grade 2 Titanium 3 Ti grade 4 Titanium 4 Ti6 AL4 V Aluminum Magnesium 5 AlMg3 Stainless steel 6 DIN 1 4305 Brass 7 CuZn Cast To alloy 8 Au 60 Pt 19 Pd 2...

Page 29: ...ENTSPLY International Inc DENTSPLY Tulsa Dental Specialties DENTSPLY International Inc 5100 E Skelly Drive Suite 300 Tulsa OK 74135 1 800 662 1202 1 800 597 2779 fax www tulsadentalspecialties com Pro...

Reviews: