3. DEFAULT PARAMETERS
This table gives the default settings of all the
programmable parameters. The default settings
will be restored whenever the "Reset"
programming label is scanned and the CCD
scanner is in programming mode.
DEFAULT VALUES OF OPERATING
PARAMETERS
Function
Default Values
Scanning Mode Selection
Trigger mode
Header and trailer
None
Inter-Message delay
Normal
Inter-Character delay
Normal
Message/Block mode selection
Message
Send command in block mode
communication
Disable
Good read beeper tone selection
2KHz/120
mSec
Code identifier transmmiting
Disable
Code 39 bar code identifier code
M
ITF 2 of 5 bar code identifier code
I
Chinese post code identifier code
H
UPC-E bar code identifier code
E
UPC-A bar code identifier code
A
EAN-13 bar code identifier code
F
EAN-8 bar code identifier code
FF
Codabar bar code identifier code
N
Code 128 bar code identifier code
K
Code 93 bar code identifier code
L
MSI bar code identifier code
P
MATRIX 25 bar code identifier code
G
2
DEFAULT VALUES OF KEYBOARD EMULATION
PARAMETERS SETTING
Function
Default Values
Keyboard type selection
IBM PC/AT USA
Message terminator
Enter/ carriage
return
DEFAULT VALUES OF RS-232C SERIAL
COMMUNICATION PARAMETERS
Function
Default Values
Handshaking protocol
None
ACK/NAK response time
setting
300 msec
Baud rate
9600
Data bit
8
Stop bit
1
Parity
Mark (None)
Message terminator
selection
CR/LF
DEFAULT VALUES OF WAND EMULATION
PARAMETERS
Function
Default Values
¡ °
Wand emulation speed
Normal
¡ °
Wand emulation output
Black = High
Note: For wand emulation, the configuration is
only effective for the items with asterisk (
¡ °
).
3