DEFAULT VALUES OF DECODING
PARAMETERS
Function
Code
Default Value
Code 39
Enable
ITF 2 of 5
Enable
Chinese Post Code
Disable
UPC/EAN/JAN
Enable
Codabar
Enable
Reading codes
¡ °
MSI
Disable
selection
Code 128
Enable
Code 93
Enable
¡ °
ITAT
Disable
¡ °
EAN-128
Disable
¡ °
MATRIX 25
Disable
¡ °
Italian Pharmac
Disable
ISSN/ ISBN
Disable
Codes
Standard
Code 39
Start/stop characters
Not transmitting
Check digit
Disabled
Concatenation
Off
Interleaved
Length
6-32 digits
2 of 5
Check digit
Disable
Chinese Post
Length
10~16 digits
Code
Check digit
Transmit
Format
All
Addendum
Disable
UPC-E=UPC-A
Disabled
UPC/EAN/JAN
UPC-A leading digit
Transmit
UPC-A check digit
Transmit
UPC-E leading digit
Transmit
UPC-E check digit
Transmit
Type
Standard
Codabar
Start/stop characters
A,B,C,D
Length
6~32 digits
Code 128
FNC 2 append
Disable
Check digit
Disable
MSI
Length
Variable
Check digit
Transmit
Italian Pharmac Transmit "A" Character Not transmitting
MATRIX 25
Length
Fix 10 digits
Check digit
Disable
4
Note: The configuration of the items with
asterisk (
¡ °
) is effective when being appointed in
advance.
4. PROGRAM PROCEDURE USING BAR CODE
MENUS
S T A R T
Rw a d S t a r t o f
C o n f i g u r a t i o n L a b e l
S e t A l l
D e f a u l t s
S e t
O p e r a t i n g
P a r a m e t e r s
S e t
Serial Port
P a r a m e t e r s
S e t
D e c o d i n g
P a r a m e t e r s
N o
Y e s
N o
Y e s
R e a d E n d o f
c o n f i g u r a t i o n
lable
R e a d A b o r t
Label
EN D
S e t
K e y b o a r d
T y p e
Finish
D i s c a r d
5