background image

 

Wireless Data Collector 

10 

 

U

SER

M

ANUAL

 

Loading Application

 

from PC 

1.

 

Follow the previous instructions to connect the data collector. 

2.

 

Select “3.Utilities/6.Application” on the data collector. 

3.

 

Select “Send Application” in ZAC. 

Loading Lookup table from PC 

1.

 

Follow the previous instructions to connect the data collector. 

2.

 

Select “3.Utilities” and “9.Load Lookup” on the data collector. 

3.

 

Select “Send Lookup” in ZAC. 

Resetting the Device 

1.

 

Press and hold the 

 and 

 buttons then press the Power button. 

2.

 

Release the Power button when you see the reset message on the screen. 

3.

 

All settings will reset to the default values. 

 

Uploading Data 

1.

 

Follow the previous instructions to connect the data collector. 

2.

 

Select “2. Upload” from the menu screen to start uploading data.   

3.

 

Select the data to be uploaded in the next screen and press enter or press ESC to 
exit. 

4.

 

Select Transfer/Direct-Link Data Transfer in Zac to start upload. 

Summary of Contents for Z-900 BT Series

Page 1: ...su Portable Data Collector Series Z 900XRF Version 1 0 User s Manual ZEBEX INDUSTRIES INC WWW ZEBEX COM Wireless Data Collector...

Page 2: ...History Changes to the original manual are listed below Version Date Description of Version 1 0 11 01 2014 Initial release 1 1 12 25 2015 Updated to new version software 1 2 12 21 2015 Added descripti...

Page 3: ...is subject to change without notice All trademarks mentioned herein registered or otherwise are the properties of their various respective owners Battery Information Use only a ZEBEX approved batterie...

Page 4: ...t source Do not place battery into a microwave oven or dryer Battery usage by children should be supervised Please follow local regulations to promptly dispose of used re chargeable batteries Do not d...

Page 5: ...Wireless Data Collector iii Copyright 2017 All rights reserved Guidance for Printing This manual is in A5 size Please double check your printer setting before printing it...

Page 6: ...3 DATA CAPTURE 4 GETTING STARTED 7 INSERTING BATTERY 7 CHARGING THE BATTERY 7 INSTALLATION 8 POWER ON THE DEVICE 8 CONNECTING TO PC 9 Connecting via Cradle 9 Running the Device on PC 9 Loading Applic...

Page 7: ...ower 17 Calculator 17 Load Lookup 18 PROGRAM MANAGER 18 Menu Description 18 Download 19 Activate 20 Upload 21 WIRELESS OPERATION 22 DOWNLOAD FILES 22 Download ZAC Files 22 Download Lookup Files 23 UPL...

Page 8: ......

Page 9: ...Creator program the device allows users to achieve maximum efficiency through intuitive settings and user friendly interfaces Features Transflective LCD for a wide working condition No programming ba...

Page 10: ...nd Strap Hole Used to attach hand straps LED Indicator Indicates reading status Red for scanning error such as wrong data type or no data match and green for good read LCD Screen Display various data...

Page 11: ...charger off timer 6 2 hrs Memory 8MB FLASH ROM 4MB SRAM with ability to data retentions Keypad 21 keys alpha numeric include Power and SCAN key with white back light LCD Screen LCD type 128 x 128 gra...

Page 12: ...ology Default Codabar Enable Code 39 Enable Code 93 Enable Code 128 Enable Code 11 Disable Italian Pharmacode Disable Chinese Post Code Disable Interleaved 2 of 5 Enable EAN UPC Enable MSI Disable Tel...

Page 13: ...Default Codabar N Code 39 M Code 93 L Code 128 K Code 11 O Chinese Post Code H Interleaved 2 of 5 I EAN 13 F UPC A A UPC E E EAN 8 FF MSI P Industrial 2 of 5 D Standard 2 of 5 S Matrix 2 of 5 G GS1 D...

Page 14: ...ix 2 of 5 Maximum 32 Minimim 6 Maximum 62 Minimim 3 Maximum 62 Minimim 3 Code 39 Code 93 Code 128 Maximum 62 Minimim 3 Chinese Post Code Maximum 16 Minimim 10 Maximum 32 Minimim 4 Interleaved 2 of 5 M...

Page 15: ...top side in first then the side with battery contact The battery is held in place by a small lock on the bottom of the compartment Push the battery in until it clicks into place 4 Slide the battery c...

Page 16: ...opens up Double click the found new hardware icon to pull up the window if it does not appear automatically Select No not this time to continue 3 Click Next to continue installation 4 Click Install f...

Page 17: ...ad and install the driver from ZEBEX website The system should assign a COM port to the device after the driver installation Connect the power adapter to the cradle when necessary Make sure the unit i...

Page 18: ...up on the data collector 3 Select Send Lookup in ZAC Resetting the Device 1 Press and hold the and buttons then press the Power button 2 Release the Power button when you see the reset message on the...

Page 19: ...r the menu option Press ESC to go to the previous screen Menu Screen Menu Description Menu Description Collect Select this option to start recording data You can scan barcodes or enter the data manual...

Page 20: ...Utility Select this option for 1 Settings 2 Browse Data 3 Delete Data 4 Reader Test 5 Set Date Time 6 Load Application 7 Memory Power 8 Calculator 9 Load Lookup when lookup is available this option be...

Page 21: ...l be activated and shoot out from the window at the lower front end of the data collector Please see the Run Task section in the User s Manual for more details 2 Aim the beam at the barcode to be scan...

Page 22: ...ble displays the numerical keys and their corresponding alphabetical characters Press the key and the numerical character corresponding to the key will be displayed Pressing the key to switch between...

Page 23: ...e communication setting for downloading Baud Rate 9600 19200 38400 57600 115200 View the baud rate for connection Backlight Turn B L off Turn B L on Turn the backlight on or off Data Deletion Manual A...

Page 24: ...to delete data Delete Data Use this option to delete inputted data 1 Select 3 Utilities and 3 Delete Data from the menu 2 Select Date File or a Lookup to delete data 3 Select All data to delete all i...

Page 25: ...the previous instructions to connect the data collector 2 Select 3 Utilities and 6 Load Application on the data collector 3 Select Send Application in ZAC Memory Power Use this option to display the...

Page 26: ...Load Lookup on the data collector 3 Select Send Lookup in ZAC Program Manager Press the numeric key 8 and power button at the same time to enter Program Manager Menu Description Menu Description Down...

Page 27: ...file After the selection connection can only be made when you place the device on the cradle 3 If you selected 1 5 in step 2 you must also select 2 Activate to begin the download procedure 4 If you s...

Page 28: ...e option from 1 5 and press Enter for detailed information 2 Press F3 to activate once in the detailed information screen 3 Press ESC to exit Program Manager after activation to begin using ZEBEX OS C...

Page 29: ...stomer Program to PC When uploading the bin file select 1 5 or A to store the file After the selection connection can only be made when you place the device on the cradle Upload 1 z900XRF_fw_x xxx 2 3...

Page 30: ...For RF SPP Master mode please select 3 Utilities 1 Settings next page 4 Wireless menu 6 Master Connect and enter the host MAC address II For RF SPP Slave mode no additional action is necessary 2 Selec...

Page 31: ...ect the correct COM port then select Start Download to begin sending files Download Lookup Files 1 To set the device to RF mode select 3 Utilities 1 Settings 2 Download Port from the device menu and s...

Page 32: ...is necessary 2 Select 3 Utilities 8 Load Lookup and wait for the device to connect An error message may appear if you fail to enter the correct MAC address in SPP Master mode 3 Connect the device to...

Page 33: ...F SPP Master mode please select 3 Utilities 1 Settings next page 4 Wireless menu 6 Master Connect and enter the host MAC address II For RF SPP Slave mode no additional action is necessary 2 Connect th...

Page 34: ...Upload Lookup Files 1 To set the device to RF mode select 3 Utilities 1 Settings 1 Upload Port from the device menu and select SPP Master or SPP Slave modes I For RF SPP Master mode please select 3 U...

Page 35: ...f you fail to enter the correct MAC address in SPP Master mode 3 Connect the device to your computer s serial port using a RF program You may need to enter a pin code to complete the pairing 4 Select...

Page 36: ...device to RF mode select 3 Utilities 1 Settings 1 Upload Port from the device menu and select SPP Master or SPP Slave modes I For RF SPP Master mode please select 3 Utilities 1 Settings next page 4 Wi...

Page 37: ...nnection to establish An error message may appear if you fail to enter the correct MAC address in SPP Master mode 6 When connection is established data will transfer to the PC Output to Record 1 Open...

Page 38: ...s serial port using a RF program You may need to enter a pin code to complete the pairing 5 Select 1 Collect from the data collector menu When you are done entering data press enter and wait for conn...

Page 39: ...enter Program Manager 3 Select 1 Download and press Enter to enter the Download screen 4 Select an empty slot to to store the file and press Enter Please remember the slot number you selected for lat...

Page 40: ...wer adapter place the unit in the cradle when ready Please install the driver if necessary 6 On your computer please open the Boot Load Utility default path Start All Programs ZEBEX ZAC Boot Load Util...

Page 41: ...e then select the firmware file stored on your computer 10 Select Start Boot Load to transfer the file to the device You will hear a beep sound when the transfer is done The Download screen appears on...

Page 42: ...turn to the Activate screen when the update is done Upgrade Warning Incorrect operation may cause dysfunction or damage to the unit Please choose the correct firmware file Do not remove power or reboo...

Reviews: