Zaxcom TRX745 Setup Menu
23
QRX / ERX Firmware Update
This menu is used to update the firmware on a QRX or ERX receiver.
If the ZaxNet mode is set to OFF or receive (RX) this menu will allow for QRX firmware to be updated – if the
ZaxNet mode is set to transmit (TX) then this menu will allow for ERX to be updated.
For complete update instructions see the FIRMWARE section in the back of this manual.
Low Battery Stop
Low battery stop will set the amount of time, after a low battery warning occurs, the on-board recorder will
close the current file and stop recording.
This is to prevent possible file corruption if the unit constantly powers off and on due to a dead battery.
•
NEVER STOP
- The onboard recorder will not stop recording unless it is manually stopped by a key press, or
when it receives a stop command via ZaxNet or if the battery dies.
•
Any interval from 1 to 99 minutes
- Once the battery indicator starts blink a low battery warning the
onboard recorder will continue to record for the time set here - then it will close the file and stop recording.
Phantom Power Enable
This menu is where 48 volt phantom power is turned on from.
OLED Brightness Adjust
This setting adjusts the brightness of the OLED display. The brightness can be set from 0 to 3 with 3 being the
brightest and 0 the dimmest. Number 2 allows for blanking the lock screen so when the transmitter is locked
the only thing that will be displayed is a single small character displaying the status of the internal recorder.
OLED Display Dim
This setting adjusts the amount of time, after the last key press, that the OLED display will dim. The dim time
can be set to OFF in which the display will remain bright or any interval from 1 to 60 seconds.
OLED BRIGHTNESS:
3
DISPLAY DIM:
OFF (NORMAL)
LOW BATT STOP:
NEVER STOP
PRESS TO SEND
QRX PROG FILE
PHANTOM POWER:
OFF