Zaxcom QRX235 IFB Extended Menu
23
Time Code Output Level Set
The time code output level sets the voltage level of the time code out of the 3.5mm time code connector. This is
useful for some cameras or time code devices that may need a different level time code signal.
Time Code Frame Rate Set
The time code frame-rate of the QIFB is set from this menu.
The QRX235 will lock to and transmit all standard time code frame rates.
•
23.98, 24, 25, 29.97DF, 29.97DF, 30 DF, 30 NDF
Time Code Jam Mode Set
The time code jam mode sets how the QRX receives and jams its time code.
•
MANUAL (OFF)
-This setting allows the time code to be manually entered in the QRX235.
•
AUTO-JAM
- The QRX235 will continuously jams time code via ZaxNet or from the UHF signal from the
transmitter - provided “USE TC FROM TRX900” is set to ON in the extended menu.
•
AUTO-LOAD
- Auto-load is used when working with record-run time code. A transmitter can start and stop
when it detects the record-run time code starting and stopping. So if the transmitter is set to auto-load as
well, and the transmitter is receiving record commands from the QRX, when the time code begins to run the
transmitter will automatically go into record.
Time Code Delay Set
The time code delay advanced or delays the time code out of the 3.5mm time code connector up to +/-50 frames
in 0.5 frame increments.
TC OUTPUT LEVEL:
1.0V (DEFAULT)
TC FRAME RATE
23.98
TC JAM MODE:
AUTO-LOAD
TC DELAY:
0 (NORMAL)