Technical Directions
for the Overhaul of
GE – GES – GEX – GEXL
Regulators/Vaporizers
DT_IS_RG-007.00-E
09/10/2009
Page 18 of 32
ZAVOLI s.r.l. Via Pitagora n° 400 47023 Fr. Case Castagnoli, CESENA (FC), Italy
Tel. (+39) 0547/ 646409 – Telefax (+39) 0547 / 646411
Web site:
www.zavoli.com
E-mail:
Fig. 3.6
Fig. 3.6-1
Diaphragm for GES – GEX – GEXL regulators/vaporizers
Fig. 3.6-2
Fig. 3.6-3
Insert the high-pressure
diaphragm hook on the bottom of
the 1
st
stage lever.
With a finger, press the 1
st
stage
lever down. The lever will sit in a
raised position, which will allow
the diaphragm hook to be
fastened to it.
FAILURE TO FASTEN THE
HOOK TO THE LEVER
WILL PREVENT THE
REGULATOR FROM
WORKING PROPERLY!
Fig. 3.6-4