SECTION 6 - MAINTENANCE
33
Zator
Via Galvani, 11 - 20095 - Cusano Milanino (MI) - Italy
www.zator.it - [email protected]
Screw* the adjustment block in the valve body with a 13mm
wrench;
5
4
*Pay
attention
that the
adjustment block is not tilted
during the screwing to avoid
damage to the thread.
NO
SI
13
!
Insert the spring:
Screw** the nozzle with a 10mm wrench;
6
**Before screwing the nozzle, check that the adjustment
screw/the micrometric adjustment handle are completely
loosened to avoid damage to the nozzle and needle. To loosen
the adjustment screw/the handle, turn it counter-clockwise
until it doesn’t resist anymore.
10