Page 65
9 PERIODIC MAINTENANCE TO BE REPEATED
AT TIMES INDICATED.
Check the wear and condition of the Contactors’ moving and fixed contacts.
Electrical Contacts should be checked every
3 months.
Check the Foot pedal or Tiller microswitch. Using a suitable test meter, confirm that there
is no electrical resistance between the contacts by measuring the volt drop between the
terminals. Switches should operate with a firm click sound.
Microswitches should be checked every
3 months.
Check the Battery cables, cables to the chopper, and cables to the motor. Ensure the
insulation is sound and the connections are tight.
Cables should be checked every
3 months.
Check the mechanical operation of the pedal or tiller . Are the return springs ok. Do the
potentiometers wind up to their full or programmed level.
Check every
3 months.
Check the mechanical operation of the Contactor(s). Moving contacts should be free to
move without restriction.
Check every
3 months.
Checks should be carried out by qualified personnel and any replacement parts used
should be original. Beware of NON ORIGINAL PARTS.
The installation of this electronic controller should be made according to the diagrams
included in this Manual. Any variations or special requirements should be made after
consulting a Zapi Agent. The supplier is not responsible for any problem that arises from
wiring methods that differ from information included in this Manual.
During periodic checks, if a technician finds any situation that could cause damage or
compromise safety, the matter should be bought to the attention of a Zapi Agent immedi-
ately. The Agent will then take the decision regarding operational safety of the machine.
Remember that Battery Powered Machines feel no pain.
NEVER USE A VEHICLE WITH A FAULTY ELECTRONIC CONTROLLER.
Summary of Contents for ZAPIMOS Series
Page 21: ...Page 21 3 8 AC3 MECHANICAL DRAWING...
Page 22: ...Page 22 3 9 AC4 MECHANICAL DRAWING...
Page 23: ...Page 23 3 10 CONNECTION DRAWING TRACTION CONFIGURATION 3 10 a Amp Saab connector...
Page 24: ...Page 24 3 10 b Molex Minifit connectors...
Page 25: ...Page 25 3 11 CONNECTION DRAWING PUMP CONFIGURATION 3 11 a Amp Saab connector...
Page 26: ...Page 26 3 11 b Molex Minifit connectors...
Page 27: ...Page 27 3 12 CONNECTION DRAWING COMBI CONFIGURATION 3 12 a Amp Saab connector...
Page 28: ...Page 28 3 12 b Molex Minifit connectors...
Page 30: ...Page 30 4 3 DESCRIPTION OF STANDARD CONSOLE MENU 4 3 a Traction configuration...