Page 57
protection. Replace the logic board.
6. CHECK UP NEEDED
This is a warning. It is an information for the user that the programmed time for mainte-
nance is elapsed.
7. INCORRECT START
This alarm signals an incorrect starting sequence. Possible causes:
a. running microswitch failure;
b. error in sequence made by the operator;
c. incorrect wiring;
d. if the default persists, replace the logic.
8. FORW + BACK
The test is carried out continuously. An alarm is signalled when a double running re-
quest is made simultaneously. Possible causes:
a. defective wiring;
b. running microswitch failure;
c. incorrect operation;
d. if the defect persists, replace the logic.
9. HANDBRAKE
The truck does not start because the handbrake switch is opened. Possible causes:
a.
defective wiring;
b.
failure of the microswitch;
c.
incorrect operation of the operator;
If the defect persist , replace the logic.
10. CAPACITOR CHARGE
Follows the charging capacitor system:
When the key is switched ON, the inverter tries to charge the capacitor through a power
resistance, and check if the capacitor are charged within a timeout. If this is not true: an
alarm is signalled; the main contactor is not closed.
Possible reasons:
a) the charging resistance is opened; if it is opened.
b) The charging circuit has a failure.
c) There is a problem on the power modules.
Summary of Contents for ZAPIMOS Series
Page 21: ...Page 21 3 8 AC3 MECHANICAL DRAWING...
Page 22: ...Page 22 3 9 AC4 MECHANICAL DRAWING...
Page 23: ...Page 23 3 10 CONNECTION DRAWING TRACTION CONFIGURATION 3 10 a Amp Saab connector...
Page 24: ...Page 24 3 10 b Molex Minifit connectors...
Page 25: ...Page 25 3 11 CONNECTION DRAWING PUMP CONFIGURATION 3 11 a Amp Saab connector...
Page 26: ...Page 26 3 11 b Molex Minifit connectors...
Page 27: ...Page 27 3 12 CONNECTION DRAWING COMBI CONFIGURATION 3 12 a Amp Saab connector...
Page 28: ...Page 28 3 12 b Molex Minifit connectors...
Page 30: ...Page 30 4 3 DESCRIPTION OF STANDARD CONSOLE MENU 4 3 a Traction configuration...