Page 30
10.3 MAIN MENU "PARAMETERS LIST"
The parameters are slightly different between tacho-generator, tacho-generator with
automatic centering and pot steering option. (the stepper motor application has the
same hand set map as the tacho-generator configuration)
After modifyng a parameter, memorize it with the hand set by pushing the "4" (OUT)
button and the "3" (IN) button. Double pushing the OUT button exits without saving the
modifications.
10.4 PARAMETERS IN SET MODEL 0 (TACHO-GENERATOR OR STEPPER
MOTOR ONLY)
1) SPEED LIMIT
Regulates the MDU maximum turning speed.
- Level 0 is for slow turning.
- Level 9 is for fast turning.
Intermediate levels are for proportionally increasing speed settings. Maximum MDU
speed has to be regulated after SET BATTERY TYPE is done (see JJ)
2) SENSIBILITY
It provides a non-linear relationship between MDU steering speed and tach-
generator voltage when low. This parameter produces increasing steering
sensitivity with small changes in steering input.
- Level 0 is for steering response that is less sensitive to small steering wheel
movements.
- Level 9 is for steering response that is very sensitive to small steering wheel
movements.
Intermediate levels are for proportionally increasing speed setting. This parameter
does not influence the maximum MDU steering rate.
Summary of Contents for EPS-AC
Page 9: ...Page 9 3 MECHANICAL SPECIFICATIONS...
Page 14: ...Page 14 6 1 ELECTRICAL DRAWING 6 1 1 Tacho generator steering...
Page 15: ...Page 15 6 1 2 Stepper motor steering...
Page 16: ...Page 16 6 1 3 Tacho generator steering with automatic centering...
Page 17: ...Page 17 6 1 4 Stepper motor steering with automatic centering...
Page 28: ...Page 28 10 1 MANUAL MODE STEERING OPTION HAND SET FUNCTION MAP...
Page 29: ...Page 29 10 2 MANUAL MODE STEERING OPTION AND AUTOMATIC CENTERING HAND SET FUNCTION MAP...