Page 20
17) PUMP ACC DELAY (p) = Pump motor acceleration time:during this time the
voltage on the pump motor goes to the desired value.
18) PUMP DEC DELAY (p) = Pump motor deceleration time:during this time the voltage
on the pump motor decreases to the desired value..
19) PUMP CREEP (p) = This parameter sets the minimum voltage applied to the pump
motor.
20) 1ST SPEED COARSE (p) = Main lift maximum speed.
21) FORK LIFT SPEED (p) = Forks lift maximum speed.
22) FORK DOWN SPEED (p) = Forks down maximum speed.
23) R - SHIFT SPEED (p) = Right shift maximum speed.
24) L - SHIFT SPEED (p) = Left shift maximum speed.
25) MIN EVP COARSE (p) = Sets the minimum voltage applied to the EVP. This is a
big regulation.
26) MAX EVP COARSE (p) = Sets the maximum voltage applied to the EVP. This is a
big regulation.
27) MIN EVP FINE (p) = Sets the minimum voltage applied to the EVP. This is a fine
regulation.
28) MAX EVP FINE (p) = Sets the maximum voltage applied to the EVP. This is a fine
regulation.
29) EVP ACC. DELAY (p) = Sets the acceleration time of the EVP.
30) EVP DEC. DELAY (p) = Sets the deceleration time of the EVP.
31) BACKING SPEED (t) = Sets the maximum backing (inching) speed.
32) BACKING TIME (t) = Sets the duration of the backing function.