Common Issues
The following problems are not a malfunction and in most situations will not require repairs.
TROUBLE SHOOTING
SAFETY PRECAUTIONS
If ANY of the following conditions occurs, turn off your unit immediately!
The power cord is damaged or abnormally warm
You smell a burning odor
The unit emits loud or abnormal sounds
A power fuse blows or the circuit breaker frequently trips
Water or other objects fall into or out of the unit
•
•
•
•
•
Issue
Possible Causes
Unit does not turn
on when pressing
ON/OFF button
Wall plug disconnected. Push plug firmly into wall outlet.
Thermostat set too low. Adjust thermostat to higher number for cooling.
Turn selector to a higher COOL position.
Thermostat set too cold for night-time cooling. To defrost the coil, set selector to a FAN
position. Then, set thermostat to a warmer position.
Air filter may be dirty. Clean filter. Refer to Care and Maintenance section. To defrost, set selector to FAN.
Thermostat set too warm. Set thermostat to colder temperature.
Temperature sensing tube touching cold coil, located behind air filter. Straighten tube away from coil.
Room temperature below 18 C(64 F). Cooling may not occur until room temperature rise above 18 C(64 F).
Unit turned off and then on too quickly. Turn unit off and wait for 3 minutes before restarting.
House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.
Selector Control in OFF position. Turn selector to the desired FAN or COOL setting.
Unit turned off by moving thermostat to a higher number and then immediately turning
back to a colder number. Wait approximately 3 minutes. Listen for compressor to start.
Air from unit does not
feel cold enough
Air conditioner cooling,
but room is too warm-
ice forming on cooling
coil behind decorative
front
Outdoor temperature below 18 C(64 F). To defrost the coil, set selector to FAN position.
Then, set thermostat to warmer position.
DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORIZED SERVICE
PROVIDER IMMEDIATELY!
Air conditioner cooling,
but room is too warm-
ice forming on cooling
coil behind decorative
front
Dirty air filter- air restricted. Clean air filter. Refer to Care and Maintenance section.
Unit recently turned on in hot room. Allow additional time to remove “Stored heat” from
walls, ceiling, floor and furniture.
Doors, windows, registers, etc. Open- cold air escapes. Close doors, windows, registers.
All directional louvers positioned improperly. Position louvers for better air distribution.
Thermostat set too warm. Turn thermostat clockwise to a colder setting.
Front of units is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in front of unit.
Dirty air filter - air restricted. Clean air filter.
Outside temperature extremely hot. Set to high cool to bring air past cooling coils more frequently.
Air conditioner turns
on and off rapidly
17
Summary of Contents for ZWACR0723V
Page 19: ...19 安裝必須由授權經銷商及受過專業訓練的人員進行 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ...
Page 22: ...此設備使用輕度易燃製冷劑R32 22 ...
Page 23: ...23 ...
Page 24: ...輕度易燃製冷劑R32 輕度易燃製冷劑 24 ...
Page 25: ...25 用戶使用手冊 用戶使用手冊 此符號表示本電器使用輕度易燃製 冷劑 如果製冷劑洩漏並暴露於外 部火源 則有著火的風險 ...
Page 26: ...26 ...
Page 27: ...27 ...
Page 30: ...ECO功能 僅限部分型號 在COOL模式下 按遙控器的ECO鍵 進入節能模式 30 紫外線 紫外線 空氣過濾器 空氣過濾器 空氣過濾器 空氣過濾器 ...
Page 32: ...32 空氣過濾器 空氣過濾器 空氣過濾器 ...
Page 33: ...33 空氣過濾器 空氣過濾器 ...
Page 34: ...34 空氣過濾器 空氣過濾器 空氣過濾器 空氣過濾器 空氣過濾器 空氣過濾器 空氣過濾器 ...
Page 36: ......