16
5.3.2
Connecting the cables
5.3.3
Electrical wires
5.3.4
Piping length and the elevation
Capacity
Watts / Btu/h
Suction/Discharge
Pipe Diameter (mm)
Standard
Length (m)
Maximum
Length (m)
Maximum
Height (m) (A)
Additional
Refrigerant (g/m
)
3517/12000
Ø9,52(3/8”)-6,35(1/4”)
4
15
5
15
5280/18000
Ø12.7(1/2”)-6,35(1/4”)
4
15
5
25
7034/24000
Ø15,88(5/8”)-6,35(1/4”)
4
15
5
30
5.3.5
Important Installation Informations
• In order to avoid extraordinary noise and vibration, the authorized service personnel must apply a proper fixation of the air
conditioner.
•
Do not block the air inlet or the air outlet.
•
Do not use the unit in places with extremely high humidity.
•
The wall must be strong enough to support the weight and vibration of the unit.
• Install the indoor unit at least 230 cm above the floor surface.
• The air filter should remain accessible.
•
Install the indoor unit in a place where the condensate water can be easily drained.
Capacity
Watts / Btu/h
System Voltage/
Frequency
Power Cord Cable
Gauge (mm²)
Connecting Cable
Gauge (mm²)
Fuse
Type (A)
Circuit
Breaker (A)
3517/12000
220-240V/50Hz.
1,5
0,75
6,3
16
5280/18000
220-240V/50Hz
2,5
0,75
6,3
16
7034/24000
220-240V/50Hz
2,5
0,75
6,3
20
Indoor Unit Connection
12K Heat Pump Type Outdoor
black
blue
brown
yellow/green
4x0,75 mm² (Signal Cable)
L
N
S
3x1,5 mm² (Power Cable)
L
N
S
yellow/green
blue
brown
1
Indoor Unit Connection
12/18/24K
Heat Pump Type
black
blue
4x0,75 mm²
brown
2
3
4
5
yellow/green
Outdoor unit
Piping length under 5m
Piping length 5m or more
Outdoor unit
Oil trap
Indoor unit
Indoor unit
(A)
(A)
(B)
(B)