Instructions for the Installer
The instructions given below are
designed specifically for a qualified
installer and should aid him or her to
perform all installation, adjustment, and
maintenance operations with absolute
precision and in compliance with all
current legislation and regulations. We
strongly recommend that all
operations for the installation of your
cooker be carryed out by Qualified Per-
sonnel in accordance with existing
rules and regulations.
Electrical connection
Prior to making the electrical connection, make sure that:
— the protection fuse and the domestic wiring
system are suitable to carry the total electric load of
the oven (see rating plate);
— your domestic wiring system has an
efficient earth connection in compliance with rules
and laws in force;
— the wall socket or the omnipole switch used
for the electrical connection can easily be reached
after the oven is built in.
This appliance is delivered without an electric supply
cable, therefore, you will have to fit to it a supply cable
with standard plug, suitable for the total electric load
shown on the rating plate. The plug is to be inserted into
a suitable wall socket. If you require a direct connection
to the electric network (mains), it will be necessary to fit
between the appliance and the mains an omnipole
switch, with a minimum gap between contacts of 3 mm,
suitable for the required load and in compliance with
rules in force. The green & yellow ground wire must
not be interrupted by the switch, and should be 2-3 cm
longer than the phase and neutral wires. The supply
cable must in all cases be laid out in such a way as to
ensure that it does not reach at any given point a
temperature 50°C higher than the ambient
temperature.
Suitable power supply cables are the following types,
considering the respective necessary section of cable:
H07 RN-F, H05 RN-F, H05 RR-F, H05 VV-F, H05
V2V2-F (T90), H05 BB-F.
Fig. 5
Terminal block
The oven is fitted with an easily accessible
terminal block (Fig. 5) which is designed to operate
with a single-phase power supply of 230 V.
Letter L
-
Live terminal
Letter N
-
Neutral terminal
or E
-
Earth terminal