Connections
Ducting Version AirExhaust System
When installing the hood in ducting version, a rigid or
a flexible pipe with the diameter corresponding to the
flange diameter is used in order to connect the hood
to the air outlet piping.
• Fix the pipe with an adequate quantity of pipe clamps
(not supplied).
• Remove possible charcoal filters.
Recirculation Version AireOutlet
• Cut a hole ø 125 mm in any shelf that may be posi-
tioned over the hood.
• Insert the flange
10a
on the hood body outlet.
• Connect the flange to the outlet on the shelf over
the hood using a flexible or rigid pipe ø120 mm.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Fix the directional grille
8
on the recirculation air outlet
using the 2 screws
12e
(2,9 x 12,7) provided.
• Ensure that the activated charcoal filters have been
inserted.
12e
8
Electrical
Connection
• Connect the hood to the mains through a two-pole
switch having a contact gap of at least 3 mm..