background image

These warnings are provided in the interests of safety. Ensure that you understand
them all before installing or using this appliance. Your safety is of paramount impor-
tance. If you are unsure about any of the meanings  of these warnings contact the
Customer Care Department.

Installation

Any installation work must be undertaken
by a qualified electrician or a competent
person.

This hood must be installed in accordance
with the installation instructions and all
measurements must be adhered to.

If the cooker hood is installed for use above
a gas appliance then the provision for
ventilation must be in accordance with the
Gas Safety Codes of Practice BS.6172,
BS.5440 and BS.6891 (Natural Gas) and
BS.5482 (LP Gas) 1994, the Gas Safety
(Installation & Use) Regulations, the
Building Regulations issued by the
Department of the Environment, the
Building Standards (Scotland)
(Consolidated) Regulations issued by the
Scottish Development Department.

The fan motor of this cooker hood
incorporates a cut-out device which will
operate if the cooker hood is installed
below the minimum height recommended
under the section ‘Clearance Height’, or if
the motor becomes overheated. If the cut-
out device is activated, switch off the fan
motor and allow the cooker hood to cool.
The cut-out device will reset itself when the
fan motor has cooled significantly.

It is dangerous to alter the specifications or
modify this product in any way.

When installed between adjoining wall
cabinets the wall cabinets must not
overhang the hob.

If the room where the cooker hood is to be
used contains a fuel burning appliance
such as a central heating boiler then its flue
must be of the room sealed or balanced
flue type.

If other types of flue or appliances are fitted
ensure that there is an adequate supply of
air to the room.

The ducting system for this appliance must
not be connected to any existing ventilation
system which is being used for any other
purpose.

Do not install above a cooker with a high-
level grill.

Child Safety

This appliance is designed to be operated
by adults. Children should not be allowed
to tamper with the appliance.

During Use

This product is for domestic use only.

Never leave frying pans unattended during
use as overheated fats and oils might
catch fire.

Never do flambé cooking under this cooker
hood.

Do not leave naked flames under the
cooker hood.

Maintenance and Service

This appliance can be a hazard if the
grease filters and charcoal filters are not
cleaned and replaced as recommended.

Under no circumstances should you
attempt to repair the appliance yourself.
Repairs carried out by inexperienced
persons may cause injury or more serious
malfunction. Refer to your local Zanussi
Service Force Centre. Always insist on
genuine spare parts.

2

1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890

1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890

1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890

1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890

1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890

1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890

1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890

1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890

IMPORTANT SAFETY INFORMATION

Summary of Contents for ZHC 950

Page 1: ...COOKER HOOD ZHC 950 INSTRUCTION BOOKLET...

Page 2: ......

Page 3: ...nts Electrical Connection Installing the Cooker Hood Installation Requirements Unpacking Clearance Heights Fitting the Wall Brackets Fitting the Canopy Hood Venting Recirculation Fitting the Chimney S...

Page 4: ...anced flue type If other types of flue or appliances are fitted ensure that there is an adequate supply of air to the room The ducting system for this appliance must not be connected to any existing v...

Page 5: ...345678901234567890123456789012123456789012345678901234567890 1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890 12345678901234567890123456789012123456789012...

Page 6: ...traction In the extraction mode the contaminated air enters the cooker hood passing through the grease filters and is passed out through the ducting into the atmosphere To obtain the best performance...

Page 7: ...de the charcoal filter absorbs smells and unwanted odours The charcoal filter cannot be cleaned or regenerated and must be replaced approximately every 4 months or more frequently if the hood is subje...

Page 8: ...l the lighting support downwards Remove the light bulb by unscrewing it anticlockwise Insert the new light bulb into the lighting support and screw it clockwise taking care not to overtighten the ligh...

Page 9: ...e to reset If after all these checks the fault persists contact your local Service Force Centre quoting the model and serial number Please note that it will be necessary to provide proof of purchase f...

Page 10: ...placed shall become the property of this company Home visits are made between 8 30am and 5 30pm Monday to Friday Visits may be available outside these hours in which case a premium will be charged EXC...

Page 11: ...ABOVE ELECTRIC HOB 7KW MAX GAS HOB 10KW MAX SLOT IN ELECTRIC COOKER 12 4KW MAX SLOT IN GAS COOKER 13 5KW MAX THIS APPLIANCE MUST BE EARTHED Electrical Requirements Any permanent electrical installatio...

Page 12: ...of this cooker hood Installation Requirements Before installation check that the wall to which the cooker hood is to be fitted for electric cables water pipes and gas This cooker hood is designed to...

Page 13: ...or 700mm 27 ins when installed above a built in gas hob A minimum clearance height of 685mm 27ins is required when installing above a slot in electric cooker or 787mm 30 ins when installed above a slo...

Page 14: ...using a spirit level and mark pen This is to ensure the correct vertical alignment of the appliance Draw a horizontal line through the vertical at 650mm above the hob Place the first bracket item 7 2...

Page 15: ...ilter must be removed Recirculation The cooker hood is supplied specified for use in the recirculation mode with the charcoal filter fitted In the recirculation mode contaminated air is passed through...

Page 16: ...of the hood body item 1 is 150mm 6 When using 125mm 5 ducting it will be necessary to install the ducting adapter item 9 to the 150mm 6 outlet on the top of the hood body and the 120mm to 125mm ducti...

Page 17: ...installed in the recirculation mode ensure that the recirculation ducting outlet extension pieces item 14 1 align correctly with the outlet grilles in the chimney Secure the sides of the chimney to t...

Page 18: ......

Page 19: ......

Page 20: ...436001681 01 030210 Electrolux plc 2002...