background image

Fitting the Hood Body

Before starting to fix the hood body,
tighten the two screws Vr located on
the top of the hood body.

Hook the hood body onto the two
4.2x44.4mm screws item 12a.

Fully tighten the screws item 12a.

Using a screw driver and spirit level,
adjust the screws item Vr until the
hood body is level.

Extraction

The cooker hood is more effective when used
in the extraction mode (ducted to the outside).

Venting kits may be purchased through
your retailer or DIY store, and must be
ducted to an outside vent of 
Ø125mm (5”)
or  
Ø150mm (6”).

The ducting used must be manufactured
from fire retardent material conforming to the
relevant British Standard or DIN 4102-B1.

When the cooker hood is ducted to the outside
the charcoal filter must be removed.

Recirculation

The cooker hood is supplied specified for use in
the recirculation mode, with the charcoal filter
fitted.

In the recirculation mode contaminated air is
passed through the charcoal filter to be purified
and recirculated into the kitchen through the
grille outlets on either side of the chimney.

To assemble the recirculation duct, place the
recirculation outlet connection item 15 into the
support  item 7.3.

Insert the extension ducts item 14.1 into either
side of the recirculation outlet item 15 ensuring
the connections are vertically and horizontally
aligned with the outlets in the chimney.

Connect the recirculation oulet item 15 to the
outlet on top of the hood body using either a
piece of Ø125mm or Ø150mm flexible or rigid
pipe.

Rigid pipe is strongly recommended and should
be used where possible as this will ensure the
best performance while lowering noise.

13

ø 150

14.1

15

12a

Vr

Summary of Contents for ZHC 950

Page 1: ...COOKER HOOD ZHC 950 INSTRUCTION BOOKLET...

Page 2: ......

Page 3: ...nts Electrical Connection Installing the Cooker Hood Installation Requirements Unpacking Clearance Heights Fitting the Wall Brackets Fitting the Canopy Hood Venting Recirculation Fitting the Chimney S...

Page 4: ...anced flue type If other types of flue or appliances are fitted ensure that there is an adequate supply of air to the room The ducting system for this appliance must not be connected to any existing v...

Page 5: ...345678901234567890123456789012123456789012345678901234567890 1234567890123456789012345678901212345678901234567890123456789012123456789012345678901234567890 12345678901234567890123456789012123456789012...

Page 6: ...traction In the extraction mode the contaminated air enters the cooker hood passing through the grease filters and is passed out through the ducting into the atmosphere To obtain the best performance...

Page 7: ...de the charcoal filter absorbs smells and unwanted odours The charcoal filter cannot be cleaned or regenerated and must be replaced approximately every 4 months or more frequently if the hood is subje...

Page 8: ...l the lighting support downwards Remove the light bulb by unscrewing it anticlockwise Insert the new light bulb into the lighting support and screw it clockwise taking care not to overtighten the ligh...

Page 9: ...e to reset If after all these checks the fault persists contact your local Service Force Centre quoting the model and serial number Please note that it will be necessary to provide proof of purchase f...

Page 10: ...placed shall become the property of this company Home visits are made between 8 30am and 5 30pm Monday to Friday Visits may be available outside these hours in which case a premium will be charged EXC...

Page 11: ...ABOVE ELECTRIC HOB 7KW MAX GAS HOB 10KW MAX SLOT IN ELECTRIC COOKER 12 4KW MAX SLOT IN GAS COOKER 13 5KW MAX THIS APPLIANCE MUST BE EARTHED Electrical Requirements Any permanent electrical installatio...

Page 12: ...of this cooker hood Installation Requirements Before installation check that the wall to which the cooker hood is to be fitted for electric cables water pipes and gas This cooker hood is designed to...

Page 13: ...or 700mm 27 ins when installed above a built in gas hob A minimum clearance height of 685mm 27ins is required when installing above a slot in electric cooker or 787mm 30 ins when installed above a slo...

Page 14: ...using a spirit level and mark pen This is to ensure the correct vertical alignment of the appliance Draw a horizontal line through the vertical at 650mm above the hob Place the first bracket item 7 2...

Page 15: ...ilter must be removed Recirculation The cooker hood is supplied specified for use in the recirculation mode with the charcoal filter fitted In the recirculation mode contaminated air is passed through...

Page 16: ...of the hood body item 1 is 150mm 6 When using 125mm 5 ducting it will be necessary to install the ducting adapter item 9 to the 150mm 6 outlet on the top of the hood body and the 120mm to 125mm ducti...

Page 17: ...installed in the recirculation mode ensure that the recirculation ducting outlet extension pieces item 14 1 align correctly with the outlet grilles in the chimney Secure the sides of the chimney to t...

Page 18: ......

Page 19: ......

Page 20: ...436001681 01 030210 Electrolux plc 2002...

Reviews: