background image

20

WARNING: Maintenance or replacement periods should be respected to avoid any fire hazards when
the filters get saturated with grease.

3.3 - Light

1 - It consists of 2 20 W-halogen spotlights.
2 - Replacement 

(fig. 30)

Remove the two screws that lock the metal ring,
take the spotlight out of its holder by pulling
slightly. When replacing, make sure that both
pins are well inserted in the holder seat.

3.4 - Cleaning

Normal cleaning operation of the hood:
-

Do not use any wet cloth or sponge or water-jet.

-

Do not use diluents or alcohol, as they could make the painted surfaces opaque.

-

Do not use abrasive products, especially on stainless steel surfaces.

We recommend the use of a damp cloth and any neutral liquid detergent.

S07_28

30

Summary of Contents for ZHC 920

Page 1: ...Cappa Cooker hood Hotte de cuisine Dunstabzugshaube Dampkap Campana ZHC 920 Istruzioni per l uso Operating Instructions Mode d emploi Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones ...

Page 2: ... illumination 2 2 No 1 telescopic chimney stack A complete with ducting fan unit 2 3 No 1 flange Ø 120 or Ø 150 F 2 4 No 1 venting grill G 2 5 No 1 ducting spigot R 2 6 No 1 support rod B 2 7 No 1 fixing kit containing No 1 wall bracket S to fix the canopy hood No 1 cover D screws rawl plugs and documentation 3 SAFETY WARNINGS 3 1 When used in the extraction mode the cooker hood ducting must not b...

Page 3: ... other appliances supplied with energy other than electric the negative pressure in the room must not exceed 0 04 mbar to prevent fumes being drawn back into the room by the cooker hood 4 INSTALLATION The versatility of the ducting fan unit on this hood enables it to be installed in one of four different ways 1 Air outlet directed upwards ducting or recirculation fitting 2 Air outlet directed towa...

Page 4: ...et directed upwards or towards the wall fig 5b c air outlet to the right or left hand side must be marked at a distance X from the line between holes 1 obtained by measuring the extension Z of the chimney required for installation plus 28 mm X Z 35 7 Using a Ø8 mm drill bit drill the points marked in this way b When installed with the air outlet directed towards the wall fig 5a it will be necessar...

Page 5: ... to the eye bolts O fixed in holes 1 fig 9 d Adjust the support rod B so that it pushes against the wall fig 10 e Adjusting position fig 11 There are two adjustable hooks at the rear of the hood which can be used to adjust its position as follows Turn the screws L until the position of screws N coincides with the lower access holes Turn the screws N to adjust the vertical and horizontal position o...

Page 6: ...p shelf only to allow the air ducting pipe to pass through fig 13 2 Direction and position of the ducting fan unit a The hood is normally supplied with the air outlet directed towards the wall fig 3 if it is to be installed with the air outlet directed to the right or left fig 4a b it will be necessary to change the direction of the ducting fan unit proceeding as follows Unscrew the screws U fig 1...

Page 7: ...mney and pull the inner section I fig 20 almost all the way out Remove the protective film P b Rest the lower section of the chimney in its housing on the top of the hood canopy Lower the ducting fan unit until it reaches the wall bracket S and fix it using the screw H provided fig 21 Fit the cover D provided on the wall bracket S fig 22 c Fix the chimney A to the hood canopy C using the four scre...

Page 8: ...ntenance Part 2 USE AND MAINTENANCE INSTRUCTIONS 1 SAFETY WARNINGS It is most important that all the warnings shown in paragraph 3 of the Installation Instructions are strictly observed Moreover pay special attention to the following warnings during the use and maintenance of the cooker hood 1 1 The grease filters and charcoal filters should be cleaned or replaced as recommended by the manufacture...

Page 9: ...grease filters 1 Cleaning It is necessary to wash these filters at least every two months with a normal detergent their compact size enables them to be washed also in dishwasher 2 Replacement The metal grease filters panels are easily removed one at a time by applying slight inward pressure to the actuators to release the securing bolts fig 28 Care should be taken to support the filter with one ha...

Page 10: ...take the spotlight out of its holder by pulling slightly When replacing make sure that both pins are well inserted in the holder seat 3 4 Cleaning Normal cleaning operation of the hood Do not use any wet cloth or sponge or water jet Do not use diluents or alcohol as they could make the painted surfaces opaque Do not use abrasive products especially on stainless steel surfaces We recommend the use ...