15
Electrical connection
Earth
(yellow/green))
Neutral
Fig. 9
The appliance is designed to be
connected to 230 V monophase
electricity supply.
The connection must be carried out in
compliance with the laws and
regulations in force.
Before the appliance is connected:
1) check that the main fuse and the
domestic installation can support the
load (see the rating label);
2) check that the power supply is
properly earthed in compliance with
the current rules;
3) check the socket or the double pole
switch used for the electrical
connection can be easily reached
with the appliance built in the forniture
unit.
The appliance is supplied with a
connection cable. This has to be provided
with a proper plug, able to support the
load marked on the identification plate.
The plug has to be fitted in a proper
socket.
If connecting the appliance directly to the
electric system, it is necessary that you
install a double pole switch between the
appliance and the electricity supply, with
a minimum gap of 3 mm. between the
switch contacts and of a type suitable for
the required load in compliance with the
current rules.
The connection cable has to be placed in
order that, in each part, it cannot reach a
temperature 90 °C higher than the room
temperature.
The brown coloured phase cable (fitted
in the terminal block contact marked with
"L") must always be connected to the
network phase.
Replacement of the voltage
cable
Only cable types H05RR-F, H05V2V2-F
T90 or H05 BB-F must be used. The
cable section must be suitable to the
voltage and the working temperature.
The yellow/green earth wire must be
approximately 2 cm. longer than the
phase wires (Fig. 6).