2.
The supply system is equipped with an effi-
cient earth connection in compliance with
the current standards and regulations
3.
The outlet or omnipolar switch used for
connection is easily accessible with the
appliance installed.
The appliance is supplied with a 3 core flexible
powercable with a 3 amp plug. If it is necessary
to change the fuse, use a 3 amp ASTA-ap-
proved (BS 1362) fuse.
A
B
C
D
E
A) Green and Yellow
B) 3 amp fuse
C) Brown
D) Cord clamp
E) Blue
The wires in the cord are coloured as follows:
Green and yellow
- Earth
Blue
- Neutral
Brown
- Live
Replacement of the connection cable
1.
Connect the green and yellow (earth) wire
to the terminal which is marked with the
letter 'E', or the earth symbol
, or col-
oured green and yellow.
2.
Connect the blue (neutral) wire to the ter-
minal which is marked with the letter 'N' or
coloured blue.
3.
Connect the brown (live) wire to the termi-
nal which is marked with the letter 'L'. It
must always be connected to the network
phase.
There must be no cut or stray strands of wire
present. The cord clamp must be correctly at-
tached to the outer sheath.
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to the
voltage load and the working temperature. The
yellow/green earth wire (B) must be approxi-
mately 2 cm longer than the live and neutral
wire (A).
A
B
Warning!
A cut off plug inserted into a 13
amp socket is a serious safety (shock)
hazard. Ensure that the cut off plug is disposed
of safely.
Important!
The replacement of electric cable
must be carried out exclusively by the service
force centre or by personnel with similar
competencies, in accordance with the current
regulations.
Assembly
min. 55 mm
min. 650 mm
550 mm
min. 100 mm
min. 600 mm
30 mm
470 mm
12