background image

WWW.ZANUSSI.COM/SHOP

867356504-C-072020

Summary of Contents for ZGGN755K

Page 1: ...GETTING STARTED EASY User Manual ZGGN755K EN User Manual Hob GB IE ...

Page 2: ...ning the use of the appliance in a safe way and understand the hazards involved Children between 3 and 8 years of age and persons with very extensive and complex disabilities shall be kept away from the appliance unless continuously supervised Children of less than 3 years of age should be kept away from the appliance unless continuously supervised Do not let children play with the appliance Keep ...

Page 3: ...urface glass surface is cracked switch off the appliance and unplug it from the mains In case the appliance is connected to the mains directly using junction box remove the fuse to disconnect the appliance from power supply In either case contact the Authorised Service Centre In case of hotplate glass breakage shut immediately off all burners and any electrical heating element and isolate the appl...

Page 4: ...llow a user or items stored beneath the hob to come in direct contact with the underside of the hob an intermediate protection panel must be fitted Plywood or kitchen carcass material is acceptable for the panel The panel must be removable for servicing Screws used to fix the panel must be accessible after installation ELECTRICAL CONNECTION WARNING Risk of fire and electric shock All electrical co...

Page 5: ... release flammable vapours Keep flames or heated objects away from fats and oils when you cook with them The vapours that very hot oil releases can cause spontaneous combustion Used oil that can contain food remnants can cause fire at a lower temperature than oil used for the first time Do not put flammable products or items that are wet with flammable products in near or on the appliance WARNING ...

Page 6: ...egulations Current Edition For appliances installed in the Republic of Ireland please refer to NSAI Domestic Gas Installation I S 813 Current Editions and the ETCI Rules for Electrical Installations Provision for ventilation Detailed recommendations are contained in the following British Standards Codes Of Practice B S 6172 B S 5440 Par 2 and B S 6891 Current Editions The hob should not be install...

Page 7: ... install the elbow correctly with the shoulder on the end of the thread fitted to the hob connecting pipe CAUTION Failure to ensure the correct assembly will cause leakage of gas CAUTION Make sure that the gas supply pressure of the appliance obeys the recommended values Rigid connection Carry out connection by using metal rigid pipes copper with mechanical end INJECTORS REPLACEMENT 1 Remove the p...

Page 8: ...rminal N Neutral terminal or E Earth terminal Before carrying out the connection make sure 1 The limiter valve and the electrical system can take the appliance load see the rating plate 2 The supply system is equipped with an efficient earth connection in compliance with the current standards and regulations 3 The outlet or omnipolar switch used for connection is easily accessible with the applian...

Page 9: ...terminal which is marked with the letter L It must always be connected to the network phase There must be no cut or stray strands of wire present The cord clamp must be correctly attached to the outer sheath ASSEMBLY 1 2 3 min 55 mm min 650 mm 560 mm 2 0 min 200 mm 30 mm 480 mm 2 0 min 600 mm 4 50 mm 400 mm If a furniture unit is installed at a distance of 400 mm above the hob there must be a mini...

Page 10: ... or drawer min 20 mm max 150 mm 30 mm 60 mm B A A Removable panel B Space for connections Kitchen unit with oven The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit PRODUCT DESCRIPTION COOKING SURFACE LAYOUT 1 4 3 2 1 Semi rapid burner 2 Multi Crown burner 3 Auxiliary burner 4 Control knobs CONTROL KNOB Symbol ...

Page 11: ...djust the flame after it is regular If after some tries the burner does not light check if the crown and its cap are in correct positions WARNING Do not keep the control knob pushed for more than 15 seconds If the burner does not light after 15 seconds release the control knob turn it into off position and try to light the burner again after minimum 1 minute CAUTION In the absence of electricity y...

Page 12: ...eats the control knob up CAUTION Make sure that pot handles are not above the front edge of the cooktop CAUTION Make sure that the pots are placed centrally on the burner in order to get the maximum stability and a lower gas consumption CAUTION Liquids spilt during cooking can cause the glass to break DIAMETERS OF COOKWARE Use cookware with diameters applicable to the size of burners Burner Diamet...

Page 13: ... aligned with the centre of the burner REMOVING PAN SUPPORTS To keep the pan supports in the correct position they are put on metal pins installed in the rear side of the hob For easier cleaning pan supports can be removed from the hob Lift up the pan supports keeping them in horizontal position as shown in the graphic Do not lift the pan supports at an angle as this will put strain on the metal p...

Page 14: ...ctly Check if the hob is correctly connected to the electrical supply The fuse is blown Make sure that the fuse is the cause of the malfunction If the fuse is blown again and again contact a qualified electrician Burner cap and crown are placed incorrectly Place the burner cap and crown correctly The flame extinguishes immedi ately after ignition Thermocouple is not heated up sufficiently After li...

Page 15: ...SER NO 03 IT MADE IN ITALY TYPE IP20 0049 A B C A Stick it on Guarantee Card and send this part if applicable B Stick it on Guarantee Card and keep this part if applicable C Stick it on instruction booklet TECHNICAL DATA HOB DIMENSIONS Width 740 mm Depth 510 mm BYPASS DIAMETERS BURNER Ø BYPASS 1 100 mm Multi Crown 57 Semi rapid 35 Auxiliary 28 15 ...

Page 16: ... FOR NATURAL GAS G20 20 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK Multi Crown 3 9 1 4 146 Semi rapid 2 0 0 6 96x Auxiliary 1 0 0 33 70 GAS BURNERS FOR LPG G30 G31 28 30 37 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK NOMINAL GAS FLOW g h G30 28 30 mbar G31 37 mbar Multi Crown 3 55 1 4 095 258 254 Semi rapid 1 9 0 6 71 138 136 Auxiliary 1 0 0 33 50 73 71 ENERGY EFFICI...

Page 17: ...size of burners Center the pot on the burner When you heat up water use only the amount you need If it is possible always put the lids on the cookware When the liquid starts to boil turn down the flame to barely simmer the liquid If it is possible use a pressure cooker Refer to its user manual ENVIRONMENTAL CONCERNS Recycle materials with the symbol Put the packaging in relevant containers to recy...