The appliance is designed to be connected to 230 V
monophase electricity supply.

The connection must be carried out in compliance with
the laws and regulations in force.

Before the appliance is connected:

1) check that the main fuse and the domestic installation

can support the load (see the rating label);

2) check that the power supply is properly earthed in

compliance with the current rules;

3) check the socket or the double pole switch used for

the electrical connection can be easily reached with
the appliance built in the forniture unit.

The appliance is supplied with a connection cable. This
has to be provided with a proper plug, able to support the
load marked on the identification plate.  To connect the
plug to the cable, follow the recommendation given in
Fig. 5. The plug has to be fitted in a proper socket.
If connecting the appliance directly to the electric system,
it is necessary that you install a double pole switch
between the appliance and the electricity supply, with a
minimum gap of 3 mm. between the switch contacts and
of a type suitable for the required load in compliance
with the current rules.
The connection cable has to be placed in order that, in
each part, it cannot reach a temperature 80 

°

C higher

than the room temperature.
The brown coloured phase cable (fitted in the terminal
block contact marked with "L") must always be connected
to the network phase.

REPLACEMENT OF THE VOLTAGE CABLE

Only cable type H05V

2

V

2

-F T90 must be used. The

cable section must be suitable to the voltage and the
working temperature.
The yellow/green earth wire must be approximately 2
cm. longer than the phase wires (Fig. 5).

5. Electrical Connection

Fig. 5

FO 0073

Neutral

Earth (yellow/green)

Summary of Contents for ZGG 646

Page 1: ...Appliance Class 3 GAS HOB ZGG 646 INSTRUCTION BOOKLET DE ...

Page 2: ...t from the electric supply During Operation About Installation Cleaning and Manteinance It is mandatory that all operations required for the installationarecarriedoutbyaqualifiedorcompetent person in accordance with existing rules and regulations Disconnect the appliance from the electrical supply before carrying out any cleaning or manteinance work Ensure a good ventilation around the appliance A...

Page 3: ...tion To put the flame out turn the knob to the symbol Always turn the flame down or put it out before taking the pans off the burner USING THE HOB CORRECTLY To ensure maximum burner efficiency it is strongly recommended that you use only pots and pans with a bottom fitting the size of the burner used so that flame will not spread beyond the bottom of the vessel see the table beside It is also advi...

Page 4: ...d detergent and bleaches impregnated pads unsuitable for non stick saucepans steel wool pads bath sink stain removers Should the hob top become heavily soiled it is recommended that a proper cleaning product is used The electric ignition is obtained through a ceramic candle and a metal electrode fig 1 lett C Keep these components well clean to avoid difficult lighting and check that the burner cro...

Page 5: ...AGB stainless steel If using flexible metallic pipes be careful they do not come in contact with mobile parts or they are not squeezed Use the same attention when the hob is combinated with an oven This hob can be operated by natural gas with nominal pressure of 20 mbar No regulation is required for use by these two types of gas Before fitting the appliance ensure that the installation hasthecorre...

Page 6: ...mendation given in Fig 5 The plug has to be fitted in a proper socket Ifconnectingtheappliancedirectlytotheelectricsystem it is necessary that you install a double pole switch between the appliance and the electricity supply with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current rules The connection cable has to be placed ...

Page 7: ...e be different or variable compared with the required pressure an appropriate pressure adjuster must be fitted on the gas supply pipe in compliance with the rules in force ADJUSTMENT OF MINIMUM LEVEL To adjust the minimum level of the burners proceed as follows Light the burner Turn the knob on the minimum position Remove the knob With a thin screwdriver adjust the by pass screw positioned in the ...

Page 8: ...mum from the hob FO 2034 a Sealing gasket FITTING THE HOB TO THE WORKTOP Before fitting the hob into the cut out an adhesive seal must be fitted to the underside outside edge Fig 9 of the hob It is essential that no gaps are left in this seal in order to prevent spillage near the hob seeping into the cabinet below 1 Remove the pan supports the burners caps and crowns and turn the hob upside down t...

Page 9: ...wn in Fig 11 The panel fitted under the hob should be easily removable to allow an easy access if a technical assistance intervention is needed Fig 13 Kitchen unit with oven The hob recess dimensions must comply the indication given in Figs 12 and 13 and must be provided with brackets to allow a continuous supply of air To avoid overhating the building in should be carried out as shown in Figs 14 ...

Reviews: