of fire). Check that the ground connection is in con-
formity with the standard and regulations force.
• Connect the appliance to the mains with a device that
lets to disconnect the appliance from the mains at all
poles with a contact opening width of minimum 3
mm, eg. automatic line protecting cut-out, earth leak-
age trips or fuse.
• None of a parts of the connection cable can not get a
temperature 90°C. The blue neutral cable must be
connected to the terminal block label with "N". The
brown (or black) phase cable (fitted in the terminal
block contact marked with "L") must always be con-
nected to the live phase.
Connection cable
Use only connection cable of type H05 V2V2-F T90.
Make sure that the cable section is applicable to the volt-
age and the working temperature. The yellow/green
earth wire must be approximately 2 cm longer than the
brown (or black) phase wire.
Assembly
min. 55 mm
min. 650 mm
550 mm
min. 100 mm
30 mm
470 mm
A
B
A - seal to remove
B - supplied brackets
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be easy to re-
move and let an easy access in case a technical assis-
tance intervention is necessary.
11