The appliance is designed to be connected to 230 V
monophase electricity supply.

The connection must be carried out in compliance with
the laws and regulations in force.

Before the appliance is connected:

1) check that the main fuse and the domestic installation

can support the load (see the rating label);

2) check that the power supply is properly earthed in

compliance with the current rules;

3) check the socket or the double pole switch used for

the electrical connection can be easily reached with
the appliance built in the forniture unit.

The appliance is supplied with a connection cable. This
has to be provided with a proper plug, able to support the
load marked on the identification plate. To connect the
plug to the cable, follow the recommendation given in Fig.
4. The plug has to be fitted in a proper socket.
If connecting the appliance directly to the electric system,
it is necessary that you install a double pole switch
between the appliance and the electricity supply, with a
minimum gap of 3 mm. between the switch contacts and
of a type suitable for the required load in compliance with
the current rules.
The connection cable has to be placed in order that, in
each part, it cannot reach a temperature 90 °C higher than
the room temperature.
The brown coloured phase cable (fitted in the terminal
block contact marked with "L") must always be connected
to the network phase.

REPLACEMENT OF THE VOLTAGE CABLE

The connection of the voltage cable to the appliance's
terminal block is of type "Y". This means that its
replacement requires the specific equipment of a
technician.
In this case, only cable type H05V

2

V

2

-F T90 must be

used. The cable section must be suitable to the voltage
and the working temperature.
The yellow/green earth wire must be approximately 2 cm.
longer than the phase wires (Fig. 4).

To open the terminal block and reach the terminals,
proceed as follows:

insert the point of a screwdriver into the visible
protrunding part of the terminal block;

exert a light pressure and lift (Fig. 5)

5. Electrical Connection

Fig. 4

Fig. 6

FO
0073

FO
0257

Neutral

Earth (yellow/green)

Fig. 5

Summary of Contents for ZDG 320 T

Page 1: ...GR GAS HOB œ ГАЗОВАЯ ВАРОЧНАЯ ПАНЕЛЬ ZDG 320 T œƒ INSTRUCTIONBOOKLET RU РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ GB ...

Page 2: ...lly before installing or using the appliance It is most important that this instruction book should be retained with the appliance for future reference Should the appliance be sold or transferred always ensure that the book is left with the appliance in order that the new owner can get to know the functions of the appliance and the relevant warnings The symbol on the product or on its packaging in...

Page 3: ...y FO 0204 A Burner cap B Burner crown C Ignition candle D Thermocouple Push the electric ignition push botton which is marked by a little spark Atthesametime turntherelevantcontroloknobanticlockwise to maximum position and keep it pushed down for about 5 seconds Thiswillallowthe thermocouple Fig 1lett D to be heated and the safety device to be switched off otherwise the gas supply would be interru...

Page 4: ...th The pan supports are dishwasher proof If the marks are particularly difficult to remove use common non abrasive cleaners or specific products Never use steel wool pads or acids In models provided with electric ignition this feature is obtained through a ceramic candle and a metal electrode Fig 1 lett C Keep these components well clean to avoid difficult lighting and check that the burner crown ...

Page 5: ... carry out the work ensureallthenecessaryprecautionsarefollowed IMPORTANT To ensure a correct operation a saving of energy and the long life of the appliance the feeding pressure of the appliance must correspond to the recommendedvalues Theadjustableconnectionisfixedtothecomprehensive ramp by means of a threaded nut G 1 2 Interpose the sealing between the components as shown in Fig 3 Screw the par...

Page 6: ...liance and the electricity supply with a minimum gap of 3 mm between the switch contacts and ofatypesuitablefortherequiredloadincompliancewith the current rules The connection cable has to be placed in order that in eachpart itcannotreachatemperature90 Chigherthan theroomtemperature The brown coloured phase cable fitted in the terminal blockcontactmarkedwith L mustalwaysbeconnected to the network ...

Page 7: ...oceed as follows Lighttheburner Turn the knob on the minimum position Removetheknob With a thin screwdriver adjust the by pass screw see Fig 8 a If changing from natural gas to LPG completely tighten clockwise the screw until a small regularflameisobtained Finally check the flame does not go out when quickly turning the knob from the maximum position to the minimum position This procedure can easi...

Page 8: ...tring fix the hob with the relevant screws Fig 10 The traction of the screws is able to trace the sealing any excess of which can then be easily removed The edge of the hob forms a double labyrinth seal which provides a total guarantee against infiltration of liquids Fig 10 FO 0199 a a sealing Fig 9 If several 30cm hob are to be installed side by side into the same cut out an assembly kit includin...

Page 9: ...chen unit with oven The hob recess dimensions must comply with the indication given in Fig 12 and must be provided with openings to allow a continuous supply of air To avoid overhating the building in should be carried out as shown in Figs 12 and 13 The hob s electric connection and the oven s one must be carried out separately both for safety reasons and to allow the oven to be easily taken off t...

Page 10: ...10 ...

Reviews: