64
TECHNICAL
SPECIFICATIONS
•
Width
594 mm
•
Depth
280 mm
•
Height
357 mm
•
Tank capacity
3 It.
•
Net weight
17 kg
•
Gross weight
19 kg
•
Power supply voltage
220 V
•
Power absorption resistors 1000 W
•
Power absorption pump
50 W
•
Working pressure
12 bar
•
Fuse 10 A.
INSTALLATION
INSTALLING IN MODULAR UNITS
For the appliance to work efficiently when installed in a
modular unit, the unit must have suitable
characteristics.
In conformity with safety standards, the appliance must
be installed correctly in order to guarantee protection
against contact between electrical parts and parts with
purely functional insulation.
All parts that act as guards, even the reveal side panel
for appliances installed at one extremity of a
combination, must be firmly secured so that they
cannot be removed without the use of tools.
It is advisable to avoid installing the appliance
immediately next to refrigerators or freezers since the
heat produced by the appliance could affect their
efficiency.
•
Warning:
-
connect the power supply cable of suitable
dimensions before securing the power supply unit.
Power supply cable specifications: wire diameter
1mm.