BYPASS DIAMETERS
BURNER
Ø BYPASS 1/100 mm
Auxiliary
29 / 30
Semi-rapid
32
Rapid
42
Dual
67
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER kW
REDUCED POWER kW
INJECTOR MARK
1/100 mm
Dual
4.5
1.8
150
Rapid
3.0
0.72
119
Semi-rapid
2.0
0.43
96
Auxiliary
1.0
0.35
70
GAS BURNERS FOR LPG G30 28-30 mbar
BURNER
NORMAL POW-
ER kW
GAS RATE g/h
REDUCED POWER
kW
INJECTOR MARK
1/100 mm
Dual
4.5
327.2
1.8
104
Rapid
3.0
218.1
0.72
88
Semi-rapid
2.0
145.4
0.43
71
Auxiliary
1.0
72.7
0.35
50
GAS CONNECTION
The gas pipe in the appliance has two endings. You
can connect the gas supply to either one of them.
The pipe that is not used must be clogged with the
pipe closer, which added to the appliance.
Use a fixed connections or use a flexible stainless
steel pipes in compliance with the regulation in
force. If you use flexible metallic pipes, make sure
they do not come in touch with mobile parts and
they are not squeezed.
23