![Zanussi ZCG 551GW User Manual Download Page 14](http://html.mh-extra.com/html/zanussi/zcg-551gw/zcg-551gw_user-manual_921283014.webp)
50
INSTRUCTIONS FOR THE INSTALLER
Safety advice
•
Before installation ensure that the local
distribution conditions (gas type and
pressure) and the pre-setting of the
appliance are consistent.
•
This appliance must be installed only in a
room with good ventilation.
•
This appliance must not connected to a flu. It
has to be installed and connected in
accordance with the rules in force. Special
attention should be paid to the applicable
disposal concerning ventilation.
•
The adjacent furniture panels have to be heat
proof or protected by such material.
•
The adjusting conditions of this appliance are
mentioned on the rating plate.
Connection to gas supply.
Check that the gas flow and the diameter of the
supply pipe is sufficient to supply all the
appliances of the installation
.
•
Check that all connections are tight.
•
Install an accessible and visible gas tap to
isolate the appliance.
The manufacturing company declines
any responsibility for possible damages
resulting from an installation which doesn't
comply with the rules in force.
INSTALLATION
Positioning
Remove all the packaging and install the cooker
in a dry, ventilated room not near curtains, paper,
alcohol, petrol etc.
The appliance must be set on a heatproof floor.
This appliance is approved to class “1” regarding
overheating of surrounding surfaces.
It is mandatory to keep 2cm distance to the
adjacent furniture.
Ventilation
Gas combustion is possible due to the oxygen in
the air (2 m
3
air/h x kW installed power – check
the rating panel of the cooker).
It is necessary to renew the air and that the
combustion products be discharged.
The air flow must come directly through openings
of external walls having a free passage of at least
200 cm
2
.
These openings should be realised preferably
positioned near the floor, opposite the
combustion products discharge. It should not be
occluded both from inside and outside.
Gas connection
Your cooker is delivered adjusted for the kind of
gas stated on the rating plate.
It might be necessary to pass to another kind of
gas, different to the one it is preset to. Under
these circumstances follow the instructions bellow.
For best efficiency, lowest consumption and
a longer length of life of your cooker, the manifold
gas pressure has to respect the values shown in
table no. 2.
2 cm
2 cm
55 cm
69
c
m