background image

5

The appliance can be installed to recirculate or extract
contaminated  air.  However,  the  cooker  hood  is  more
effective in the extraction mode.

Recirculation

The contaminated air is cleaned by passing through the
filters and then back into the kitchen.

Extraction

The contaminated air enters the hood passing through
the  grease  filter  and  out  through  the  ducting  to  the
atmosphere.

When the ducting position is selected
the charcoal filter is not required.
Never do flambé cooking under this
cooker hood.
Never leave frying pans unattended during use
as over-heated fats and oils can catch fire.
Do not leave naked flames under the
cooker hood.

Ensure the visor is open when using the
hob even if the fan on the hood is not
switched on.

Ensure heating areas on your hob are
covered with pots and pans when using
the hob and cooker hood simultaneously.

Summary of Contents for TH 500

Page 1: ...INTEGRATED COOKER HOOD TH 500 INSTRUCTION BOOKLET ...

Page 2: ...emove the Grease Filter Cassette Charcoal Filters To Remove Replace the Charcoal Filters Worktop Lighting Replacing the Strip Light Replacing the Strip Light Starter Something Not Working Service Force Centres To register ownership please ensure you complete and return the guarantee card supplied with the appliance Peace of Mind for Twenty Four Months Standard Guarantee Conditions For the Installe...

Page 3: ...he cut out device will reset itself when the fan motor has cooled significantly It is dangerous to alter the specifications or modify this product in any way When installed between adjoining wall cabinets the wall cabinets must not overhang the hob If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed or...

Page 4: ... Microswitch The microswitch overrides the controls and switches off the hood when the visor is closed When the visor is opened the hood will resume the function of previous setting Fan ON OFF control Position 1 Low Position 2 Normal Position 3 Boost Light ON OFF control To Operate Extend the visor and select the required functions To obtain the best performance it is advisable to switch on the ho...

Page 5: ...ease filter and out through the ducting to the atmosphere When the ducting position is selected the charcoal filter is not required Never do flambé cooking under this cooker hood Never leave frying pans unattended during use as over heated fats and oils can catch fire Do not leave naked flames under the cooker hood Ensure the visor is open when using the hob even if the fan on the hood is not swit...

Page 6: ... damage the surfaces Always wear protective gloves when cleaning the hood Never use scouring pads or abrasive cleaners Never use excessive amounts of water when cleaning particularly around the control panel Metal Grease Filters The metal grease filters should be cleaned at least every month The filters may be washed by hand using mild soapy water or they can be machine washed in a dishwasher To r...

Page 7: ...fuser screws through the end capping on the right hand side 2 Slide the diffuser to the left until the opposite end is free then pull the diffuser down 3 Remove the fluorescent tube and replace with one of the same specification 4 Replace the cover and the retaining screws Replacing the strip light starter 1 Open the visor and remove the grease filter cas sette 2 Unscrew the two fixing screws whic...

Page 8: ...quately vented to allow the entry of fresh air If set up for recirculation check that the charcoal filter is still effective If set up for extraction check that the ducting and outlets are not blocked The safety cut out device has been tripped Tum off the hob and then wait for the device to reset In guarantee customers should ensure that the above checks have been made as the engineer will make a ...

Page 9: ... parts of glass or plastic Costs incurred for calls to put right appliances improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are the subject of rental agreements Products of Zanussi manufacture which are not marked by Zanussi This guarantee is in addition to your statutory and legal rights ZANUSSI ...

Page 10: ...stallation must comply with the latest I E E Regulations and local Electricity Board regulations For your own safety this should be undertaken by a qualified electrician e g your local Electricity Board or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting NICEIC Electrical Connection Before connecting to the mains supply ensure that the main...

Page 11: ...pipes or gas Ducting The ducting must be fire retardant 125mm 5ins in diameter and the length should be nomore than 3 metres with one 90 bend 2 metres with two 90 bends Bends of more than 90 will reduce the efficiency of the hood and reduce the airflow Clearance Height The cooker hood is designed to be fitted over a cooking appliance at the clearance heights stated providing the maximum output of ...

Page 12: ...f the wall cabinet is less than 450mm a gap of 50mm must be maintained either side of the hob This cooker hood must not be installed above a cooking appliance with a high level grill Unpacking Before unpacking the cooker hood position the carton with the arrows pointing upwards as illustrated on the carton Positioning This cooker hood is designed to be fitted into a cabinet which should have a min...

Page 13: ...rk the position for the cut out for the ducting on the top of the kitchen cabinet ensuring that the centre of the hole aligns with the centre of the ducting spigot A pad saw or similar cutter will be required to cut the rectangular hole for the cooker hood and the circular hole for the ducting spigot Before inserting the cooker hood inside the cabinet ensure a hole has been provided to route the m...

Page 14: ...t the casing is supported at all times Fitting the Control Panel The control panel support should be located on the right hand side in the channel on the underside of the hood Using the screws provided secure the control box support into the pre drilled hole Clearance Height The cooker hood can be concealed behind a decor panel by removing the factory fitted front strip and fitting a length of lig...

Page 15: ...15 ...

Page 16: ...16 ...

Page 17: ...17 ...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...4324166 04 010913 Electrolux Household Appliances Limited 2000 ...