11
Commissioning
When the hob has been fully installed it will be necessary
to check the minimum flame setting. To do this, follow
the procedure below.
- Turn the gas tap to the MAX position and ignite.
- Set the gas tap to the MIN flame position then turn
the control knob from MIN to MAX several times. If
the flame is unstable or is extinguished follow the
procedure below.
Procedure:
Re-ignite the burner and set to MIN.
Remove the control knob, use a thin bladed
screwdriver to turn the adjustment screw. Check
the flame is steady and does not extinguish when
the knob is turned from MIN to MAX. Repeat this
procedure for all burners.
)
)
)
)
)
Technical Maintenance
Check at regular intervals the condition and serviceability
of the gas connection hose and pressure regulator, if any
is fitted; in case of malfunction, do not repair but replace
the whole faulty part.
To ensure a smooth and safe operation, it is necessary
to periodically grease the gas taps.
by-pass
screw