7
SOLUTION
Check that the unit is plugged in and the electrical
supply is switched on.
Check the mains fuse has not blown.
Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
Check the main jet is not blocked and the burner
crown is clear of food particles.
Check the burner cap and crown have been
replaced correctly, e.g. after cleaning.
Something Not Working?
If the appliance is not working correctly, please carry out the following checks before contacting your local Service
Centre.
SYMPTOM
There is no spark when lighting the gas
The gas ring burns unevenly
If after all these checks, your appliance still does not operate correctly, contact your local Service Centre.
Overall dimensions
Width:
580 mm
Depth:
500 mm
Height:
84 mm
Cut out dimensions
Width:
550 mm
Depth:
470 mm
Instructions for the Installer
Engineer technical data
Supply Connections
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230 V 50 Hz supply, 3 core flexible cable with non
rewireable plug.
Appliance Gas supply
: LPG 30 mbar
Appliance Class
: 3
Appliance category
: I 3
Burner
Nominal Power LPG (Butane "A") Diameter
Feeding
Tap. By-Pass
Pressure
kW
kCal/h
Nozzle
g/h
mbar (*)
Auxiliary
0,95
814
50
75
28
Semi-rapid
1,60
1368
65
126
35
30
Triple crown
3,60
3080
98
284
56
(*) 1 mbar = 10 mm. water coloumn.